3) To reset the alarm history, press and hold both the 
 service button and the MANUAL 
DEFROST button for 5 seconds.
4) Press the MANUAL DEFROST button to return to the menu screen. Press and hold 
both the
 
 button and the 
 service button for 5 seconds to exit the setting mode 
and return to the temperature display.
g) Compressor Run Time (F7)
To display the compressor run time between the two most recent defrosts, follow the 
steps below.
1) Press and hold both the
 
 button and the 
 service button for 5 seconds. "F0" should 
appear in the display window. Press the MANUAL DEFROST button until "F7" appears 
in the display window.
2) Press the 
 service button to display the run time. The number displayed indicates 
what percent of the time the compressor was running.
3) Press the MANUAL DEFROST button to return to the menu screen. Press and hold 
both the
 
 button and the 
 service button for 5 seconds to exit the setting mode 
and return to the temperature display.
h) Not in Use (F8)
The display flashes "--" and "00" when this unused setting is viewed.
i) High Temperature Shutoff Temperature Setting (FA)
This value should only be changed after consulting with the factory. To change the high 
temperature shutoff temperature setting, follow the steps below.
1) Press and hold both the
 
 button and the 
 service button for 5 seconds. "F0" should 
appear in the display window. Press the MANUAL DEFROST button until "FA" appears 
in the display window.
2) Press the 
 service button to display the current setting (default: 163°F (73°C) for 
refrigerators and 158°F (70°C) for freezers; Note that for °F, only the last two digits are 
displayed and "-" flashes). Press the 
 up or 
 down button to increase or decrease 
the high temperature shutoff temperature setting. 
Note: The value can be adjusted between 149 to 167°F (65 to 75°C).
3) Press the 
 service button to save the setting.
4) Press the MANUAL DEFROST button to return to the menu screen. Press and hold 
both the
 
 button and the 
 service button for 5 seconds to exit the setting mode 
and return to the temperature display.
j) Not in Use (Fb)
This unused setting can be set to either "AL" or "12". The setting has no affect on the 
performance of the unit.