1
Note: Each relay has a corresponding light. For the condenser fan (X5), compressor 
(X4), defrost heater (X1), and door light (X) relays, the light is "on" when the 
component is receiving power, and "off" when the component is not receiving 
power from the board. For the evaporator fan relay (X3), the opposite is the case; 
the light is "off" when the evaporator fan is receiving power, and "on" when the 
evaporator fan is not receiving power from the board. 
Evercheck Control Board
K9 (red)
K1 (white)
K5 (black)
K4 (red)
(grey/cabinet)
K3 (white)
(orange/defrost)
Alarm Reset Button
Output Test Button
K6 (white)
K (white): Transformer 
K8: Communication 
Cable (Dual Temp only)
K7: Display Cable
Dip Switch 
Thermistors
X3
X
X1
X4
X5
X5 Relay: Condenser Fan
X4 Relay: Compressor
X1 Relay: Defrost Heater
X Relay: Door Light 
X3 Relay: Evaporator Fan 