Chapter 2  Unpacking and Moving the Library
Moving the Library to the Final Installation Area
Quantum|ATL 7100 Series Facilities Planning and Installation Guide
17
Moving the Library to the Final Installation Area
2
To move the library to the final installation area:
1
Based on the information above, prepare the path to the final 
installation area.
2
Verify that all leveling feet are fully retracted. If the feet are not 
fully retracted, rotate each of the four feet counterclockwise 
until they are fully retracted.
3
Roll the library to the final installation area.
Warning:
The library weighs approximately 500 lb. Use two 
people to move the library.
Note:
When moving the cabinet, one person should guide the 
library from the rear while the other person pushes from 
the front. Do not push the library up or down a ramp 
with an incline greater than 10
°
.
Caution:
The library has a nominal floor clearance of 0.75" 
(1.9cm). Place stiff plastic or rubber mats on top of 
carpeting that depresses more than the nominal 
clearance and over floor cracks and door jambs prior 
to rolling the library over them.
Caution:
Any side of the library can be used to push the library 
to the final installation area. However, it is preferred 
to push from the front of the library. When pushing 
from the front, DO NOT push on the following non-
structural portions:
• Load port door
• Control panel
• Front door
• Front door handle