Setting the Time Data
C
h
ap
te
r 2
  
Pr
ep
ar
a
tio
ns
Advancement of internal time code 
generator 
The internal time code generator can advance in either of 
two modes, which can be set with the RUN MODE menu 
item (see page 65).
FREE RUN: Advancement starts when the data saving 
operation is completed.
REC RUN: Advancement starts when recording starts and 
stops when recording stops.
To set the current time as the initial time 
code value
In step 2 above, set the RUN MODE menu item to FREE 
RUN, then set the current time (format: HH:MM:SS:FF = 
hours: minutes:seconds:frame number) in step 3 and 
subsequent steps.
Synchronizing Internal and External 
Time Codes
The internal time code generator can be synchronized with 
an external time code (LTC) input to this unit.
To synchronize the internal time code to 
external time code
Input an external time code (LTC) signal to the TIME 
CODE IN connector, then set the TC MODE menu item 
(see page 65) to EXT REGEN.
The internal time code generator locks onto the external 
time code and starts advancing. Once the internal time 
code generator has been synchronized in this way, you can 
disconnect the external time code input and this unit will 
maintain the synchronized time code.
Note
When the selected input mode is “i.LINK” (the i.LINK 
indicator is lit in the INPUT signal display section), setting 
the TC MODE menu item to EXT REGEN causes the 
internal time code generator to automatically synchronize 
with the external time code input to the unit via the i.LINK 
interface.
When the TC SELECT menu item is set to VITC, the 
internal time code generator synchronizes to the time code 
(VITC) of video input signals. 
Once an external time code signal has been input, the 
internal time code advancement mode and frame count 
mode are automatically set as follows:
Advancement mode: FREE RUN
Frame count mode: Same as external time code (drop 
frame or non-drop frame)
To confirm external synchronization
Press the STOP button to put the unit into stop mode, then 
press the REC button.
Look at the time counter display and check that the time 
code value displayed there matches the external time code 
value.