Troubleshooting
C
h
a
p
ter
 8
in
te
na
nc
an
T
rou
b
le
s
h
o
o
ti
ng
Troubleshooting
If an alarm message appears on the monitor screen, or if 
the unit appears to be malfunctioning, please check the 
following before contacting your Sony dealer.
Recording/playback problems
Symptom
Cause
Remedy
Recording is not 
possible.
Disk is full.
Delete unneeded data.
The unit’s recording/
playback control 
buttons (PLAY, NEXT, 
PREV, etc.) do not 
work.
The REMOTE indicator in the display 
section is lit and the LOCAL ENABLE 
menu item is set to STOP or ALL 
DISABLE.
Set the control mode selector to LOCAL to turn the REMOTE 
indicator off, or change the setting of the LOCAL ENABLE 
menu item (see page 62) to ALL ENABLE. 
Key operations are disabled (KEY 
INHI).
Set the control mode select switch to the LOCAL side.
Time data problems
Symptom
Cause
Remedy
Cannot freely set the 
initial time data value.
The TC MODE menu item is set to EXT 
REGEN.
Change the setting of the TC MODE menu item (see page 
65)
 to INT PRESET.
CNT is selected as the time data type 
to be displayed (the COUNTER time 
data type indicator is lit).
Press the COUNTER SELECT button to make the TC or U-
BIT time data type indicator light up (the CNT value cannot 
be set freely).
The REMOTE indicator in the display 
section is lit and the LOCAL ENABLE 
menu item is set to STOP or ALL 
DISABLE.
Set the control mode selector to LOCAL to turn the REMOTE 
indicator off or change the setting of the LOCAL ENABLE 
menu item (see page 62) to ALL ENABLE.
During recording or 
playback the time data 
is not shown in the time 
counter display.
The MENU button has been pressed.
Press the button once again to exit the menu control mode, 
time code preset mode, or digital hours meter display mode. 
(In either of the menu control mode and time code preset 
mode, the time data is not shown in the time counter display.)
The U-BIT time data type indicator is lit. Press the COUNTER SELECT button to make the 
COUNTER or TC time data type indicator light up.
Monitor problems
Symptom
Cause
Remedy
Data is not 
superimposed on the 
monitor screen.
The CHARA. DISPLAY menu item is 
set to OFF.
Set the CHARA. DISPLAY menu item (see page 63) to ON.
The monitor is not connected to the 
SUPER connector of this unit.
Connect the monitor to the SUPER connector. (You must 
make this connection to display any type of text on the 
monitor.)
The image on the 
monitor screen is too 
bright.
The 75 
Ω termination switch for video 
input on the monitor is in the OFF 
position, or a 75 
Ω terminator is not 
fitted to its video input connector.
Set the 75 
Ω termination switch to ON or connect a 
terminator.
The image on the 
monitor screen is too 
dark. 
In a video signal loop-through 
connection of video monitors, 75 
Ω 
termination switches for video input on 
monitors other than the loop-end 
monitor are in the ON position.
Set the 75 
Ω termination switches to OFF on all monitors 
other than the loop-end monitor.
The image is too dark 
when recording a 
composite video 
signal.