Руководство Пользователя для Calculated Industries Construction Master Pro

Скачать
Страница из 110
U
SER
S
G
UIDE
— 61
(Cont’d)
KEYSTROKE
DISPLAY
3. Find regular incremental Jack adjustment and regular Jack rafter
lengths and cut angles:
j
JKOC 
16 
INCH
*
j
INCR  1 
FEET
6-1/2 
INCH
j
JK 1  8 
FEET
2-3/8 
INCH
j
JK 2  6 
FEET
7-7/8 
INCH
j
JK 3  5 
FEET
1-3/8 
INCH
j
JK 4  3 
FEET
6-13/16 
INCH
j
JK 5  2 
FEET
0-5/16 
INCH
j
JK 6  0 
FEET
5-13/16 
INCH
j
JK 7  0 
FEET
INCH
j
PLMB  30.26°
j
LEVL 59.74°
j
CHK1  45.00°
*If display does not read JKOC 16 INCH (the default), then reset On-center spacing
by pressing 
1 6 i ß 5
.
Jack Rafters — 
Using Other Than 16-Inch On-Center Spacing
A roof has a 9/12 Pitch and a run of 6 Feet 9 Inches. Find the incre-
mental jack adjustment, jack rafter lengths and cut angles at 18-inch
(versus 16-inch) On-center spacing. The On-center spacing is used
for both Regular and Irregular Jack calculations.
KEYSTROKE
DISPLAY
1. Enter Pitch, Run and spacing:
o o
0.
9 i p
PTCH  9 
INCH
6 f 9 i R
RUN  6 
FEET
INCH
1 8 i ß 5 
(o.c.)
OC 
18 
INCH
2. Find regular incremental Jack adjustment and regular Jack rafter
lengths and cut angles:
j
JKOC 
18 
INCH
j
INCR  1 
FEET
10-1/2 
INCH
j
JK 1  6 
FEET
6-3/4 
INCH
j
JK 2  4 
FEET
8-1/4 
INCH
j
JK 3  2 
FEET
9-3/4 
INCH
j
JK 4  0 
FEET
11-1/4 
INCH
j
JK 5  0 
FEET
INCH
j
PLMB  36.87°
j
LEVL 53.13°
j
CHK1  45.00°
3. Reset On-center spacing to default 16-inch:
1 6 i ß 5 
(o.c.)
OC 
16 
INCH
STORED
STORED
STORED
STORED