PreRelease Manual PN 119985 Rev 09-26-05 Firmware Rev 3 
Ensure the brew basket is in place.  Place a suitably graduated container in place below the brew basket to capture 
and measure the water delivered.  To calibrate, enter the service mode as noted above and advance to the “CAL” 
screen.  Press either the left or right brew button and water delivery will begin.  If the brewer has not reached 
operating temperature, it will finish heating before automatically starting.  The pump will cycle on and off for 
approximately 2 minutes at which time the currently programmed volume is displayed.  Use the left and right button to 
decrement or increment the value to the measured value.  For better accuracy, you may want to measure a couple of 
cycles and average the measured values.  Note that user mode will be entered automatically when exiting the service 
mode if calibration values have been changed. 
 
Service Data consist of the tank temperature as measured at two points in the tank and an indication as to which 
probe(s) are making contact with the  water.  To view data, enter the service mode as noted above and advance to 
the “Srv” screen.  Use the left or right button to enter service data mode.  Use the center button to advance through 
the data.  The table below list the data that is displayed. 
 
Data displayed 
Screen 
Example 
Values 
Available 
Comment 
Lower Temperature 
198 
N/A 
Degrees F 
Upper Temperature 
20
.
N/A Degrees 
Probes 
1:Sr 
S,r,Sr 
Displays probes in contact with the water; Standard, RO or Both. 
Exit 
End 
N/A 
Use left or right button when displayed to exit this mode. 
 
User Mode is entered by holding any of the buttons on the face of the machine while powering up the brewer.  Note 
that the user mode is also automatically entered whenever the calibration volume setting is changed.  The beverage 
volume, brew time, and visa-brew time can be programmed for each of the three buttons on the face of the brewer.  
The brewer will determine the minimum brew time possible based on pump speed and calibration values as outlined 
previously.  This time is set as the default whenever calibration values are changed.  The brew time can be extended 
to lengthen the water delivery time to meet a specific beverage taste profile.  The table below list the data displayed 
and values available. 
 
Data displayed 
Screen 
Example 
Values 
Available 
Comment 
Brew 1 Settings 
b1 
N/A 
Displays briefly to indicate that the parameters are for brew 
button 1 (left) 
Brew 1 Volume 
64 
Off, 30-128 
Ounces.  Button can be turned off and will serve as cancel only. 
Brew 1 Time 
3:30 
Min-9:59 
Calculated minimum to 9 minutes and 59 seconds. 
Visa-brew 1 Time 
0:30 
0:00-4:00 
Set to allow for beverage to finish dripping from basket after 
water delivery time has been completed. 
Brew 2 Settings 
B2 
N/A 
Displays briefly to indicate that the parameters are for brew 
button 2 (center) 
Brew 2 Volume 
64 
Off, 30-128 
Ounces.  Button can be turned off and will serve as cancel only. 
Brew 2 Time 
3:30 
Min-9:59 
Calculated minimum to 9 minutes and 59 seconds. 
Visa-brew 2 Time 
0:30 
0:00-4:00 
Set to allow for beverage to finish dripping from basket after 
water delivery time has been completed. 
Brew 3 Settings 
b1 
N/A 
Displays briefly to indicate that the parameters are for brew 
button 3 (right) 
Brew 3 Volume 
64 
Off, 30-128 
Ounces.  Button can be turned off and will serve as cancel only. 
Brew 3 Time 
3:30 
Min-9:59 
Calculated minimum to 9 minutes and 59 seconds. 
Visa-brew 3 Time 
0:30 
0:00-4:00 
Set to allow for beverage to finish dripping from basket after 
water delivery time has been completed. 
Exit 
End 
N/A 
Use left or right button when displayed to exit this mode.