I. INSTALLATION INSTRUCTIONS
1. INSTALLATION:
(i) 
Installation of this broiler must conform with the latest edition of  ANSI Z223.1/NFPA National Fuel 
Gas Code in USA ( CSA-B-149.1 or 2 Installation Code in Canada) and/or local codes.
(ii) 
Use  this  Broiler  only  with  an  adequately  sized  exhaust  hood. The  room  in  which  this  broiler  is 
installed must be suitably vented in accordance with the National and or local codes.
(iii)
n
2. ACCEPTABLE CLEARANCES:
Due to intense heat generated by radiation,  only non-combustible construction should be provided. In USA 
and Canada these broilers should be installed in non-combustible locations only.
I  MASSACHUSETTS: All gas products must be installed by a “Massachusetts” licensed plumber 
or gas fitter. Ventilation hoods must be installed in accordance with NFPA-96, current edition, with 
interlocks as described in that standard.
(i) 
Minimum Clearance From Non-Combustible Construction.
   Right
   Left 
   Back     
Floor
      0
     0
      0
       4" (100 mm)
3. GAS CONNECTION:
A  separate  gas  shut  off  valve  (supplied  with  unit) 
must be installed in a readily accessible location in 
the  gas  line  ahead  of  the  pressure  regulator  (see 
figure “A”). The gas pressure regulator supplied must 
be installed on the gas inlet pipe of the broiler (see 
below). Each regulator is adjusted to yield a pressure 
of 3.5" water column (9 mbar) for Natural Gas or 10" 
water column (25 mbar) for Propane Gas.
All products used with combustible gas, including gas 
pressure  controls,  must  be  installed  and  used 
strictly  in  accordance  with  the  manufacturer's 
instructions and all applicable government codes and 
regulations and plumbing practices.
Figure “A”
Do not use the gas pressure regulator if it appears to have been tampered with or damaged in any way as 
this may affect proper operation and may create potentially dangerous conditions.
Install the regulator properly with the direction of gas flowing as indicated by the arrow on the casting. (The 
arrow must be pointing to the Gas Appliance).
Use a pipe compound or thread sealant that is compatible with the gas supplied to the regulator and apply it 
in accordance with the manufacturer's recommendation. 
Apply  wrench  pressure  only  to  the  flat  area  at  the  threaded  end  of  the  regulator  closest  to  the  gas 
appliance to avoid fracturing the regulator body.
Make sure markings or paintings on the regulator are not painted over or otherwise obliterated.
Check carefully for gas leaks immediately after the regulator has been installed and the gas turned on. Do 
this before attempting to operate the appliance. 
Use a soap and water solution (or other accepted leak 
tester) around all pipe joints. It is a good practice to periodically check for gas leaks during use of the 
appliance. Do not use the appliance if a gas leak is detected.
3
MAIN SHUT-OFF VALVE
PRESSURE REGULATOR