Руководство По Установке для KitchenAid 30-Inch 5-Burner Dual Fuel Convection Slide-In Range with Baking Drawer

Скачать
Страница из 48
24
Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator (LP Gas to 
Natural Gas)
1. Move the range out about 1 ft (30.5 cm) from the wall.
2. Locate the gas pressure regulator at the lower right corner on 
the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
3. Unscrew the metal cover and unscrew the blue regulator cap. 
Keep the washer in place.
4. Flip the blue regulator cap over and screw it back into the 
metal cover.
5. Screw the metal cover securely back into place. Do not 
overtighten.
To Convert Surface Burners (LP Gas to Natural Gas)
1. If they are installed, remove the burner grates.
2. Remove the burner caps.
3. Remove the burner base. 
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
A. Gas pressure regulator
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 
instructions.
Slide range back so rear range foot is engaged in the 
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 
and engaged.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C
A
A. Metal cover
B. Washer
C. Blue regulator cap
A. LP gas position
B. Natural gas position
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
A
B
A
C
A
B
D
A
B
C