Справочник Пользователя для Netgear M4300-8X8F (XSM4316S) - Stackable Managed Switch with 16x10G including 8x10GBASE-T and 8xSFP+ Layer 3
Maintenance and Troubleshooting
673
M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual
The default value is 33434. The range is 1- 65535. The port you enter is not retained
across a power cycle.
across a power cycle.
13.
Enter the Size of the probe packets.
The default value is 0. The range is 0 to 39936. The size you enter is not retained across
a power cycle.
a power cycle.
14.
Enter the Source IP address or interface to use when sending the echo request packets.
If source is not required, select None as the source option. Possible values are as
follows:
follows:
•
None
. The source address of the ping packet would be the address of the default
outgoing interface.
•
IP Address
. The source IP address to use when sending the echo request packets.
This field is shown when IP Address is selected as the source option.
•
Interface
. The interface to use when sending the echo request packets. This field is
shown when Interface is selected as the source option.
Note:
Values configured in the fields on this page are not saved to the switch.
As a result, refreshing the page sets these fields to the default values.
As a result, refreshing the page sets these fields to the default values.
15.
Click the Apply button.
The traceroute begins. The results display in the TraceRoute area.
The Results field displays t
he traceroute IPv6 result after the switch sends a traceroute
request to the specified IP address or host name.
Packet Capturing
You can capture and store packets on a USB flash storage device.
To initiate packet capturing:
1.
Launch a web browser.
2.
Enter http://<ipaddress> in the web browser address field.
The login window opens.
3.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
4.
Click the Login button.
The System Information page displays.
5.