24 English  
Installation requirements
Ins
tallation r
equir
ement
s
This range is designed to operate at a 
pressure of 5 in (13 cm) of water column on 
natural gas or 10 in (25 cm) of water column 
on LP gas (propane or butane).
Make sure you are supplying your range 
with the type of gas for which it is designed. 
Do not attempt to convert the appliance 
from the gas specified in this manual to a 
different gas without consulting the gas 
supplier.
This range is convertible for use on natural 
or propane gas. If you decide to use this 
range on LP gas, conversion must be made 
by a qualified LP installer before attempting 
to operate the range.
For proper operation, the pressure of natural 
gas supplied to the regulator must be 
between 5 in and 13 in (13 cm and 33 cm) 
of water column. 
For LP gas, the pressure supplied must be 
between 10 in and 13 in (25 cm and 33 cm) 
of water column.
When checking for proper operation of the 
regulator, the inlet pressure must be at least 
1 in (2.5 cm) greater than the operating 
(manifold) pressure as given.
The pressure regulator located at the inlet 
of the range manifold must remain in the 
supply line regardless of whether natural or 
LP gas is being used. 
A flexible-metal appliance connector used 
to connect the range to the gas supply 
line should have an I.D. of 0.5 in (1.3 cm) 
and be 5 ft (152 cm) in length for ease of 
installation. In Canada, flexible connectors 
must be single-wall metal connectors no 
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal 
tubing when moving the range.
Gas requirements 
Provide adequate gas supply