Chapter 2  Installation
Setting the DIP Switches
By setting the DIP switches at the back of the AIT autoloader, you can:
• Supply power to the SCSI terminator (on by default)
When you are using several SCSI devices, you can set the AIT autoloader to 
supply power to the SCSI terminator.
• Display warning messages when specific parts reach the end of their life or 
when in need of cleaning (on by default)
You can set the AIT autoloader to display warning messages when specific 
parts reach the end of their service life or when need of cleaning (weekly).
• Use the autoloader option function (off by default)
You can set the AIT autoloader to monitor the AIT drive status on a regular 
basis, as well as automatically eject and insert cartridges.
The default settings of the DIP switches are as follows.
Switches are off when in the “0” position and on in the “1” position. The default 
setting of the DIP switches is indicated in brackets.
1 TERM PWA (on)
0: Power is not supplied to the SCSI terminator.
1: Power is supplied to the SCSI terminator.
1
2
3
4
5
6
7
8
0
off
1
on
DIP switches for setup
Rear
DIP SW (DEFAULT)
off on
1
0
8
TERM PWR 
MAINTENANCE 
LOADER SEL
     CONTINUOUS
     AUTOLOAD
RMIC
RESERVED
RESERVED