Справочник Пользователя для Q-Logic 3000

Скачать
Страница из 120
B–Flash Update
QLogic Adapter Flash Update—Linux
B-10
NE0154601-00  C
Flash Update Procedure
To update the Linux OS Flash:
1.
Ensure that the steps required for installing the RPM source, creating the 
binary, and installing the binary to the file system have been performed. If 
not, follow the instructions in 
 before proceeding. The new driver is now ready to be 
loaded automatically the next time the system is powered up.
2.
Update the Flash. 
a.
Type the following command to go to the appropriate directory:
% cd/opt/netxen
b.
Type the following command to display a list of all the QLogic devices:
./nxflash --list
Note the function number for the QLogic adapter.
c.
Type the following command to start the Flash update; use the function 
number from the previous step in the -i option:
% ./nxflash -i [n] --all
The Flash update takes a few minutes to complete and must not be 
interrupted
. Note that you only need to update one port on each QLogic 
adapter; updates do not need to be performed on a per-port basis.
As an example, the --list command displays one of the following two 
devices in an SFP+ installation. For copper -based installations, additional 
devices will be shown:
[0]  NetXen Dual Port SFP+ 10GbE Server Adapter [PCI slot 17 
function 0]
[1]  NetXen Dual Port SFP+ 10GbE Server Adapter [PCI slot 17 
function 1]
3.
Get Flash related information. Use the --info option to get information 
about the Flash by typing:
%  ./nxflash -i [n] --info