INSTALLATION
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
AIR FOR COMbUSTION AND VENTILATION
Continued
Figure 2 - Ventilation Air from Inside 
Building
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills 
Into Adjoining Room,
Option 2
Ventilation
Grills Into
Adjoining 
Room,
Option 1
12"
12"
Ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
Figure 3 - Ventilation Air from Outdoors
items directly to the outdoors or spaces open 
to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel 
Gas  Code,  ANSI  Z223.1/NFPA  54,  Air  for 
Combustion and Ventilation
 for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
NOTICE: State or local codes may 
only allow operation of this appli-
ance  in  a  vented  configuration. 
Check your state or local codes.
 WARNING: Before installing 
in a solid fuel burning fireplace, 
the  chimney  flue  and  firebox 
must be cleaned of soot, creo-
sote, ashes and loose paint by a 
qualified chimney cleaner. Creo-
sote will ignite if highly heated. 
A dirty chimney flue may create 
and  distribute  soot  within  the 
house. Inspect chimney flue and 
firebox for damage. If damaged, 
repair  flue  and  firebox  before 
operating heater.
  WARNING:  Seal  any  fresh 
air vents or ash clean-out doors 
located on floor or wall of fire-
place. If not, drafting may cause 
pilot  outage  or  sooting.  Use  a 
heat-resistant  sealant.  Do  not 
seal chimney flue damper.