Справочник Пользователя для INSTEON 2475d

Скачать
Страница из 13
                                                                                                                                  Page 10 of 13                                                                                 Rev: 1/21/2014 7:17 AM 
Voltage 
120 volts AC +/- 10%, 60 Hertz, single phase 
Power Wire Leads 
6", 16 AWG, stranded,600V, 105°C insulation, ends stripped 
and tinned, LINE (black), LOAD (red), NEUTRAL (white) 
Ground Lead 
6”, 18 AWG, stranded, bare copper 
Maximum Dimmer Load 
600 watts (uses 12-Amp triac dimmer) 
Maximum Amps 
2.5 amps 
Standby power consumption 
0.78 watts 
Certifications 
Safety tested for use in USA and Canada (ETL #3017581) 
X10 Features 
X10 Primary Address 
1 optional (comes unassigned) 
X10 Status Response 
Supported 
X10 Resume Dim 
Supported by setting local on-level to zero 
X10 Powerline Frequency 
120 KHz 
X10 Minimum Transmit Level 
3.2 Vpp into 5 Ohms 
X10 Minimum Receive Level 
20mV into 5 Ohms 
X10 Messages Repeated 
No 
Troubleshooting 
 
Problem
 
Possible Cause
 
Solution
 
In-LineLinc’s status LED 
is not turning on at all 
and In-LineLinc won't 
control my light. 
 
In-LineLinc is not getting 
power. 
 
Make sure the circuit breaker is turned on. 
 
Check junction box wires to ensure all 
connections are tight and no bare wires are 
exposed. 
 
Check the light fixture to ensure all connections 
are tight and no bare wires are exposed. 
 
The switch I'm replacing 
only has two wires. 
 
In-LineLinc needs a Neutral 
wire in order to operate. 
 
Look in the rear of the junction box for a group 
of white wires all tied together with a wire nut. 
Those are the Neutral wires. Connect the 
Neutral In-LineLinc wire there. 
 
In-LineLinc is not 
receiving signals from 
INSTEON or X10 
controllers. 
 
In-LineLinc and the controller 
are on opposite powerline 
phases. 
 
Make sure two Access Points (#2443) or other 
 are properly 
installed to detect the two powerline phases. 
 
The controller is plugged into 
a power strip. 
 
Powerline signals can't travel through power 
filters. Plugging the Controller directly into a 
wall outlet works best. 
 
Other modules are loading 
down the signal. 
 
Move the other modules or the controller to 
another outlet. 
 
In-LineLinc is not linking 
to or working with an 
INSTEON controller or 
device. 
 
The INSTEON signal may be 
too weak. 
 
Add new INSTEON devices or move around 
existing INSTEON devices. All INSTEON 
devices act as INSTEON network repeaters. 
 
Make sure you are not experiencing