2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM 
 
Troubleshooting 
Problem 
Possible Cause 
Solution 
The LEDs on Micro 
module are not turning on 
at all  
Micro module is not getting 
power 
Make sure the circuit breaker is turned on 
Check junction box wires to ensure all 
connections are tight and no bare wires are 
exposed 
Check the light fixture to ensure all 
connections are tight and no bare wires are 
exposed 
The switch I’m replacing 
only has two wires 
Micro module needs a neutral 
wire in order to operate 
Look in the rear of the junction box for a group 
of wires tied together with a wire nut. Those 
are commonly neutral wires. 
Pull a neutral from nearby junction box 
Micro module is not 
receiving signals from 
INSTEON or X10 
controllers 
The controller is plugged into 
a power strip 
Powerline signals can’t travel through some 
power filters. Plug controller into wall outlet. 
Other modules are 
attenuating the signal or 
causing noise on the line 
Plug other modules into a signal filter or move 
the modules or controller to another outlet 
INSTEON devices act as network repeaters. 
Add new or move existing INSTEON devices 
and retest. 
Micro module and the 
controller are on opposite 
powerline phases 
Make sure there are at least 2 dual-band 
INSTEON products are properly installed to 
bridge the phases 
The light turned on by 
itself 
Another controller, a timer, or 
stray X10 signals triggered 
Micro module 
Install a power line signal blocker in your home 
to keep X10 signals from neighboring homes 
from interfering. Consider not using Micro 
module in X10 mode.  
Micro module may have an 
undesired responder 
membership 
Use software to remove membership or 
perform a factory reset and re-setup Micro 
module 
The controlled light does 
not appear to turn on or 
off right away 
Responder’s scene ramp rate 
might be quite slow 
Set a faster ramp rate and relink responder 
Micro module responds to 
on commands but not off 
commands 
Load connected to Micro 
module is producing electrical 
noise that is interfering with 
the Micro module reception of 
powerline signal 
Install an inline signal filter between the load 
and Micro module 
Install additional INSTEON devices to boost 
the INSTEON signal 
I can’t turn Micro module 
on (but I can turn it off, 
brighten and dim it) 
The on-level may be set to 
fully-off or very dim 
Set a brighter on-level. See 
. 
When I try to turn on my 
Micro module may be set up  Remove the X10 address from Micro module