Справочник Пользователя для Jacuzzi led series j-220

Скачать
Страница из 43
page 32
16.0 J-210/J-220 Convertible Circuit Diagram (60Hz)
This wiring diagram is used for the J-20/J-220 US/Canada 20/240 
VAC (60Hz) convertible power models.
Optional
Ozonator
O3
Standard 3-Wire 120 VAC Connection (60 Hz, 1 Phase, 15A Service)
Use copper conductors ONLY.  Wire size must be appropriate per NEC and/or local codes.
WHT
WHT
WHT
WHT
WHT
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
RED
RED
RED
*
RED
*
RED
*
RED
Heater
1.0 kW @ 120 VAC (3-wire connection)
4.0 kW @ 240 VAC (4-wire connection)
Pressure Switch
Hi-limit/Freeze Sensor
Temperature Sensor
J2
J3
F1
20A
250V
SC-20
Main Pump
Spa Light
Transformer
120 VAC
Optional 4-Wire 240/120 VAC Convertible Heater Connection
1.  Remove and discard the factory installed GFCI Cord.
2. Move 
RED
wire from TB1 position #1 to TB1 position #3 as shown below.
3.  Permanently connect to the power supply.  Use copper conductors ONLY.  
Wire size must be appropriate per NEC and/or local codes.
4.  If hot tub is to be operated on 30A service, make sure the jumper provided 
at location JP1 #1&2 on the circuit board is installed.  If  hot tub is to be 
operated on 40A service, remove the jumper JP1 #1&2 on the circuit board.
HI
LO
J1 Logic Jumper Settings (Factory Defaults Shown)
JP -2 oN    =  30A Logic (4-wire 20/240 VAC operation only)
JP -2 oFF  =  40A Logic (4-wire 20/240 VAC operation only)
JP 7-8 oN    = °C Temperature Display
JP 7-8 oFF  = °F Temperature Display
This device complies with Part 15 of the
FCC rules.  Operation is subject to the 
following two conditions:
1. This device may not cause harmful 
interference.
2. This device must accept any inteference 
received including interference that may 
cause undesired operation.
J20
J2
J2
J4
J6
J
J5
J3
J7
J7
J8
J9
J0
J5
J6
Heater IN
Heater oUT
F
K5
K7
K8
J1
Control 
Panel
THERM
SWITCH
7
5
3
1
8
6
4
2
To circuit board
GRN
Tb1
WHT
BLK
1
2
3
1
2
3
GR
OUND
GRN
Tb1
WHT
BLK
GR
OUND
WARNINg, ELECTRICAL SHOCK HAZARD ExISTS!  Always remove power to spa before wiring 
and/or configuring the circuit board
Move Wire
Hard
Wire 
Only
Plug-in 
GFCI 
Cord (US 
Models 
Only) OR
Hard 
Wire