1.6.4 ENGINE 
SPECIFICATIONS
Type of Engine ........................................................................GT-530
Cooling Method ................................................................ Air-cooled
Rated Horsepower ...................................................18 at 3600 rpm
Displacement ........................................................................... 530cc
Compression Ratio ................................................................8.5 to 1
Cylinder Block .................................. Aluminum w/Cast Iron Sleeve
Type of Governor .......................................Electronic, Fixed Speed
Engine Governor Speed ................................................... 2571 rpm
Air Cleaner ................................................................. Paper Element
Starter ..................................................................12-volt DC Electric
Ignition System ............................  Solid-state w/Flywheel Magneto
Recommended Spark Plug
  NGK ....................................................................................BPR6HS
Spark Plug Gap .............................................0.030 inch (0.76 mm)
Recommended Min. Battery .................. 400 Cold Cranking Amps
Class II Emission Certified
1.7  
EXHAUST EMISSIONS 
INFORMATION (GASOLINE)
The Environmental Protection Agency (EPA) and the California Air 
Resource Board (CARB) require that this generator comply with 
exhaust emission standards. The generator is certified to meet all 
applicable exhaust emission levels. This generator is certified for 
use as a mobile engine. It is important that you follow the mainte-
nance specifications listed in this manual to ensure that the engine 
complies with emission standards for the duration of its life. This 
engine is certified to operate on gasoline. The emission control 
system on the generator consists of the following:
Fuel Metering System
• 
~ Carburetor assembly
~  Fuel pump and lines
Air Induction System
• 
~  Intake pipe / manifold
~ Air cleaner
Ignition System
• 
~ Spark plug
~ Ignition module
Catalytic Converter (if equipped)
• 
The Emissions Compliance Period referred to on the Emissions 
Compliance Label indicates the number of operating hours for 
which the engine has been shown to meet Federal and California 
emission requirements. See the table below to determine the com-
pliance period for this generator. The displacement of the engine is 
listed on the Emissions Compliance Label.
Displacement
Category
Compliance Period
> 66 cc - < 225 cc
A
500 Hours
B
250 Hours
C
125 HOurs
≥ 225 cc
A
1000 Hours
B
500 Hours
C
250 Hours
1.6.3   
GENERATOR SPECIFICATIONS
SERIES
RV45G
RV55G
RV65G
Rotor RPM
3600
3600
3600
Rotor Poles
2
2
2
Engine RPM
2571
2571
2571
Rated Max. Continuous AC Output Watts*
4500
5500
6500
Voltage*
120
120
120
Rated Max. Continuous Current Amps (240V)
37.5 (18.7)
45.8 (22.9)
54.1 (27)
Phase
1
1
1
Frequency
60 Hertz
60 Hertz
60 Hertz
Weight
278 lbs.
285 lbs.
293 lbs.
Length
33.7 in.
33.7 in.
33.7 in.
Width
21.5 in.
21.5 in.
21.5 in.
Height
16.8 in.
16.8 in.
16.8 in.
*    All units are re-connectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output
**   Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power 
decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.