Справочник Пользователя для IceRobotics Limited ICE3DST3

Скачать
Страница из 24
3. INSTALLATION
This section contains  step-by-step instructions on  how to install the IceTagAnalyser  2008 
software  onto  your PC, how to  activate  and communicate  with  IceTag3D motion  sensors 
using IceReader and how to attach and remove an IceTag3D device to an animal.  
3.1 Installing the IceTagAnalyser 2008 Software
Insert the IceTagAnalyser 2008 CD into the CD-ROM drive on your PC and follow the step-
by-step guide to run the setup program on the IceTagAnalyser 2008 CD.
3.2 Connecting the IceReader 
Using the USB cable provided connect the IceReader to any USB port on your PC.  The first 
time the IceReader is connected, the operating system may prompt for a driver installation. 
On most versions of Microsoft Windows the drivers for the IceReader are included in the 
Microsoft Windows operating system.  Therefore no driver installation should be necessary.
The green LED on the IceReader will be illuminated if the IceReader is being powered.  The 
amber LED will illuminate on the IceReader when the IceTagAnalyser 2008 software has 
recognised the IceReader and is ready for use. 
If   the   amber   LED   on   the   IceReader   does   not   illuminate,   then   driver   installation   may   be 
required. These  can be installed from the IceTagAnalyser 2008 software CD. Simply re-run 
the setup application for IceTagAnalyser 2008 and select the ‘Full’ installation option instead 
of ‘Typical’ installation. A ‘Typical’ installation will not install the drivers as most versions of 
Windows XP already have the required drivers pre-installed. The setup program will install the 
drivers   in   a   sub-directory   alongside   IceTagAnalyser;   this   is   typically   C:\Program 
Files\IceRobotics\IceTagAnalyser\USB  Drivers.   A  document   called   ‘DriverInstallation   DI3D-
001-001.pdf’, found in the ‘USB Drivers’ folder, details how to register the installed drivers 
with your system. 
3.3 Communicating with an IceTag3D Motion Sensor Device
To   activate   or   communicate   with   an   IceTag3D   device   swipe   the   IceTag3D   over   the 
IceReader.   The amber LED on the IceTag3D will flash to indicate that the IceTag3D has 
been   read.     To   verify   that   the   system   is   functioning   correctly   check   that   the   IceTag3D 
information is displayed on the screen.  This section describes IceTagAnalyser and its use.
3.4 Attaching an IceTag3D Device to an Animal
The  IceTag3D   is   attached   to   an   animal’s   hind   leg   using   the   Velcro   strap   provided.   The 
IceTag3D   should   be   mounted   with  the   red   arrow   pointing   upwards.   Figure   1   shows   a 
correctly attached IceTag3D and illustrates the attachment in three steps:
1. Thread one end of the Velcro strap through the smaller, left hand side lug.  The smooth, 
yellow side of the Velcro should face inwards against the animal’s leg. Press the Velcro 
back onto itself to fasten.
2. Loop the strap around the animal’s leg and through the bigger, right hand side lug.
3. Press the Velcro back onto  itself to fasten.   Check the attachment is loose enough to 
allow two to three of your fingers to be inserted between the strap and the animal’s leg.