4.  Configuring the LT4424 
4.1 EEPROM P
ARAMETERS
 
A Host can program various parameters that are stored in EEPROM and become active after a power-
on reset.  Table 6 – EEPROM Parameters, gives the locations and descriptions of the parameters that 
can be read or written by a Host.  Factory default values are also shown.  Do not write to any EEPROM 
addresses other than those listed below.  Do not copy a transceiver’s EEPROM data to another 
transceiver.  Doing so may cause the transceiver to malfunction. 
Table 6 – EEPROM Parameters 
Parameter 
EEPROM 
Address 
Length 
(Bytes)  Range 
Default 
Description 
Product ID 
00H 
40 
 
 
40 bytes - Product identifier string.  
Includes revision information for software 
and hardware. 
Channel 
Number 
40H 
00 – 0Fh 
00h 
Refer to Table 8 
Server/Client 
Mode 
41H 
01 – 02h 
02h 
01h = Server 
02h = Client 
Baud Rate Low 
42H 
00 – FFh 
05h 
Low Byte of the interface baud rate. 
Baud Rate High  43H 
00 – FFh 
00h 
High Byte of the interface baud rate. 
Control 0 
45H 
 
00010100b 
(14h) 
Settings are: 
Bit 7 – Laird Technologies Use Only 
Bit 6 – Laird Technologies Use Only 
Bit 5 – Reserved (Set to Zero) 
Bit 4 – Laird Technologies Use Only 
Bit 3 – Packet Frame 
0 = Disable Packet Frame 
1 = Use pin 12 as Packet Frame 
Bit 2 – Laird Technologies Use Only 
Bit 1 – RF Delivery 
0 = Addressed 
1 = Broadcast 
Bit 0 – Laird Technologies Use Only 
Transmit 
Retries 
4CH 
01 – FFh 
10h 
Maximum number of times a packet is 
sent out when Addressed Packets are 
selected. 
Broadcast 
Attempts 
4DH 
01 – FFh 
04h 
Maximum number of times a packet is 
sent out when Broadcast Packets are 
selected.