Справочник Пользователя для Itron Inc. 100GDLCS

Скачать
Страница из 52
 
This chapter provides instructions to install the 100G ERT module on 175 - 250 CFH National (Lancaster) 
meters.  
 
 
Removing the Meter Index 
Begin the module installation by removing the index cover and index from the meter. 
 
To remove the index from the meter 
1.  Remove any tamper seals from the index cover screws. Remove the index cover screws and the index 
cover from the meter. Discard the index cover mounting screws and index cover. The 100G includes new, 
different-size ERT module mounting screws  
 
Note  You may use the removed index cover as a temporary storage container for screws. Properly 
dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not 
leave materials on customer premises.  
2.  Remove one index mounting screw completely. Hold one hand under the index to catch the screw.  
3.  While you remove the other mounting screw, pull the index away from the meter to keep the index 
backplate against the back of the screw.  
C
H A P T E R  
5  
National (Lancaster) Meter Installation 
TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 
49  
 
Proprietary and Confidential