Справочник Пользователя для Intel S1200BTLR DBS1200BTLR

Модели
DBS1200BTLR
Скачать
Страница из 153
Jumper Blocks 
Intel® Server Board S1200BT TPS 
 
 
Revision 1.0 
Intel order number G13326-003 
104 
8.  Jumper Blocks 
The server board has several 3-pin jumper blocks that can be used to configure, protect or 
recover specific features of the server board. 
 
Figure 46. Jumper Blocks (J4A2, J1F1, J1F3, J1F2, and J1E2) on S1200BTL 
Table 42. Server Board Jumpers (J1F1, J1F2, J1F3, J1E2, and J4A2) on S1200BTL 
Jumper Name 
Pins  
System Results 
J1E2: CMOS 
Clear 
1-2 
These pins should have a jumper in place for normal system operation. (Default) 
2-3 
If these pins are jumpered with AC power plugged, the CMOS settings are cleared within 
five seconds. These pins should not be jumpered for normal operation. 
J1F2: ME 
Force Update 
1-2 
ME Firmware Force Update Mode 
– Disabled (Default) 
2-3 
ME Firmware Force Update Mode 
– Enabled 
J1F1: 
Password Clear 
1-2 
These pins should have a jumper in place for normal system operation. (Default) 
2-3 
If these pins are jumpered, administrator and user passwords are cleared within 5-10 
seconds after the system is powered on. These pins should not be jumpered for normal 
operation. 
J1F3: BIOS 
Recovery 
1-2 
These pins should have a jumper in place for normal system operation. (Default) 
2-3 
Given that the main system BIOS will not boot with these pins jumpered, system can only 
boot from EFI-bootable recovery media with the recovery BIOS image. 
J4A2: BMC 
Force Update 
1-2 
Integrated BMC Firmware Force Update Mode 
– Disabled (Default) 
2-3 
Integrated BMC Firmware Force Update Mode 
– Enabled