Справочник Пользователя для Intel S1200BTLR
Intel® Server Board S1200BT TPS
Appendix B: Integrated BMC Sensor Tables
Revision 1.0
Intel order number G13326-003
125
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading Type
Event Offset Triggers
Contrib. To System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-by
Power Supply 2
+12V % of Maximum
Current Output
+12V % of Maximum
Current Output
(PS2 Curr Out %)
59h
Chassis-
specific
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
De
Analog
R, T
A
X
Power Supply 1
Temperature
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
De
Analog
R, T
A
X
Power Supply 2
Temperature
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
specific
Temperature
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
De
Analog
R, T
A
X
Processor Status
(P1 Status)
70h
All
Processor
07h
Sensor Specific
6Fh
01 - Thermal trip
Fatal
As and
De
De
–
Trig
Offset
Offset
M
X
07 - Presence
OK
Processor Thermal
Margin
Margin
(P1 Therm Margin)
74h
All
Temperature
01h
Threshold
01h
__
__
-
Analog
R, T
A
–
Processor Thermal
Control %
Control %
(P1 Therm Ctrl %)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
De
Analog
Trig
Offset
Offset
A
–
Catastrophic Error
(CATERR)
80h
All
Processor
07h
Digital Discrete
03h
01
– State Asserted
Non-fatal
As and
De
De
–
Trig
Offset
Offset
M
–
MSID Mismatch
(MSID Mismatch)
81h
All
Processor
07h
Digital Discrete
03h
01
– State Asserted
Non-fatal
As and
De
De
–
Trig
Offset
Offset
M
–
Processor
Population Fault
Population Fault
(CPU Missing)
82h
All
Processor
07h
Digital Discrete
03h
01
– State Asserted
Fatal
As and
De
De
–
Trig
Offset
Offset
M
–
Processor VRD
Temperature
Temperature
(P1 VRD Hot)
90h
All
Temperature
01h
Digital Discrete
05h
01 - Limit exceeded
Fatal
As and
De
De
–
Trig
Offset
Offset
M
–
Power Supply 1 Fan
Tachometer 1
(PS1 Fan Tach 1)
Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
specific
Fan
04h
Threshold
01h
–
–
–
Analog
–
–
–
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
specific
Fan
04h
Threshold
01h
–
–
–
Analog
–
–
–