Справочник Пользователя для Intel S1200BTLR

Скачать
Страница из 153
Platform Management 
Intel® Server Board S1200BT TPS 
 
 
Revision 1.0 
Intel order number G13326-003 
44 
Task 
Capabilities & Features 
2.0  
and Thermal Policy 
Limit power upon power excursion (OS operational) 
 
Reduce power upon temperature excursion 
 
Limit power even when OS is not operational (OS failure) 
 
Avoid Triggering 
HW Protection 
Reduce power consumption to prevent tripping DC circuit breaker 
 
Power supply optimization technologies (SmaRT & CLST) used to 
limit power consumption to reduce demand on power supplies in 
specific scenarios. 
 
Interfaces 
IPMI-based commands over SMBus (monitoring, control & alert) 
 
PECI Proxy and Pass-Through (this feature is also available on the 
ME Si-Enabling firmware) 
 
Power telemetry from Integrated BMC or from PMBus-compliant 
power supplies 
Note:
 
EPSD systems have ME get power data directly from power 
supplies 
 
4.4.3 
Role of Integrated BMC in NM 
This section summarizes the Integrated BMC role in the NM feature implementation. 
4.4.3.1 
External Communications Link 
The Integrated BMC provides the access point for remote commands from external 
management software and generates alerts to that software.
 
The ME plays the role of an IPMI 
satellite controller that communicates to the Integrated BMC over a secondary IPMB. There are 
mechanisms to forward commands to ME and send response back to originator. Similarly 
events generated by ME to the Integrated BMC (via IPMB) have to be sent by the Integrated 
BMC to the external software over the LAN link. It is the responsibility of Integrated BMC to 
implement these mechanisms for communication with Node Manager (NM). 
4.4.3.1.1 
Command Passing Via Integrated BMC 
External software 
wishing to communicate with the NM will send ‗bridged‘ IPMI commands to 
Integrated BMC. This will be in the form an IPMI packet encapsulated in another packet, 
following standard IPMI bridging as described in the IPMI 2.0 Specification. Integrated BMC 
forwards the encapsulated command it to NM engine on the ME and returns the response to 
the sender. 
Due to the fact that some of the NM commands have potential for performance limiting and 
system shut-down, the Integrated BMC firmware enforce an administrator privilege for any 
commands bridged to the ME. 
4.4.3.1.2 
Alerting 
Alerts may be sent from the NM in the ME to the external software by one of two different 
methods depending on the nature of the alert.