Справочник Пользователя для Intel S1200BTLR

Скачать
Страница из 153
Intel® Server Board S1200BT TPS 
BIOS User Interface 
Revision 1.0 
   
Intel order number G13326-003 
77 
 
 
Main 
Advanced 
Security 
Server Management 
Boot Options 
Boot Manager 
 
 
 
 
Assert NMI on SERR 
Enabled / Disabled 
Assert NMI on PERR 
Enabled / Disabled 
Resume on AC Power Loss 
Stay Off / Last state / Power On 
Clear System Event Log 
Enabled / Disabled 
 
FRB-2 Enable 
Enabled / Disabled 
 
O/S Boot Watchdog Timer  
Enabled / Disabled 
O/S Boot Watchdog Timer Policy 
Power off / Reset 
O/S Boot Watchdog Timer Timeout 
5 minutes / 10 minutes / 15 minutes / 20 minutes 
 
► Console Redirection 
► System Information 
► Hardware Monitor
 
 
 
Figure 26. Server Management Screen (S1200BTS) 
6.5.2.13 
Console Redirection 
The Console Redirection screen allows the user to enable or disable console redirection and to 
configure the connection options for this feature. 
To access this screen from the Main screen, select Server Management > Console 
Redirection
. To move to another screen, press the <Esc> key to return to the Server 
Management
 screen, then select the desired screen. 
 
 
 
Server Management 
 
 
 
Console Redirection 
 
 
Console Redirection 
Disabled / Serial Port A / Serial Port B 
Flow Control 
None / RTS/CTS 
Baud Rate 
9.6k / 19.2k / 38.4k / 57.6k / 115.2k 
Terminal Type 
PC-ANSI / VT100 / VT100+ / VT-UTF8 
Legacy OS Redirection 
Disabled / Enabled 
 
 
Figure 27. Console Redirection Screen