I/O expansion options
The server supports up to five PCIe slots with different riser cards installed into two riser sockets on the 
system planar (one riser socket supports the installation of one riser card). There are two types of riser 
cards: 2U risers and 1U risers. 2U risers are used in x3630 M4 models that do not have the rear HDD 
cage assembly (see Figure 4). 1U risers are used in models with the rear HDD cage assembly installed 
(see Figure 5). See Figure 4 and Figure 5 for slot locations and numbering.
Note: You cannot use 1U risers in models without the rear HDD cage. You cannot use 2U risers in models 
with the rear HDD cage assembly installed.
The slot form factors with 2U risers (models without the rear HDD cage assembly) are as follows:
Slot 1: PCIe 3.0 x16 (x8-wired), optional PCIe 3.0 x16 (x16-wired); full-height, full-length
Slot 2: PCIe 3.0 x16 (x8-wired); full-height, half-length (not present if optional x16-wired slot 1 riser is 
used)
Slot 3: PCIe 3.0 x16 (x8-wired), optional PCIe 3.0 x16 (x16-wired); low-profile, half-length (the second 
processor is required to use this slot)
Slot 4: PCIe 3.0 x16 (x8-wired); low-profile, half-length (not present if optional x16-wired slot 3 riser is 
used, the second processor is required to use this slot)
Slot 5: PCIe 3.0 x8 (x4-wired); dedicated slot for ServeRAID adapter; standard on hardware RAID 
models, optional on software RAID models
Note: Standard models with software RAID (ServeRAID C105) ship with one 2U riser supplying slots 1 
and 2 (slots 3, 4, and 5 are not present). Standard models with hardware RAID adapters (ServeRAID 
M1115 or M5110) ship with two 2U risers supplying all five slots. See Table 10 for details.
The slot form factors with 1U risers (models with the rear HDD cage assembly) are as follows:
Slot 1: PCIe 3.0 x8 (x8-wired), optional PCIe 3.0 x16 (x16-wired); full-height, half-length
Slot 2: PCIe 3.0 x8 (x8-wired); low-profile, half-length (not present if an optional x16-wired slot 1 riser 
is used)
Slot 3: PCIe 3.0 x8 (x4-wired), optional PCIe 3.0 x8 (x8-wired); dedicated slot for ServeRAID adapter 
(x8-wired slot requires the second processor, x4-wired slot does not require the second processor)
Note: The 3.5" Hot Swap Cage Assembly, Rear, 2 x 3.5" option, part number 00D9034, ships with two 1U 
risers supplying x8-wired slots 1 and 2 and x4-wired slot 3. See Table 10 for details.