Информационное Руководство для IBM Express x3300 M4 7382E4G

Модели
7382E4G
Скачать
Страница из 52
IBM System x3300 M4
34
For the latest information about the specific versions and service levels supported and any other 
prerequisites, see the IBM ServerProven® website:
 
Physical and electrical specifications
The  x3300 M4 server has the following dimensions and weight (approximate):
In tower configuration:
Width: 235 mm (9.25 in), 176 mm (6.9 in) without stabilizer feet
Depth: 678 mm (26.7 in), 605 mm (23.8 in) without front bezel
Height: 438 mm (17.1 in). 425 mm (16.7 in) without stabilizer feet
Weight minimum: 22.0 kg (48.5 lb)
Weight maximum: 29.7 kg (65.4 lb)
In rack configuration (with rack conversion kit):
Width: 481 mm (18.9 in)
Height: 176 mm (6.9 in) (4U)
Depth: 625 mm (24.6 in) excluding bezel (bezel and HDD handles adds 24 mm)
Minimum: 20.5 kg (45.2 lb)
Maximum: 28.2 kg (62.1 lb)
The  x3300 M4 server has the following supported environment:
Server on:
Temperature: 5°C - 40°C (41°F - 104°F) up to 950mm (3,117ft) 
Above 950m, de-rated maximum air temperature 1°C / 175m. 
Humidity, non-condensing: -12°C dew point (10.4°F) and 8% - 85% relative humidity 
Maximum dew point: 24°C (75°F) 
Maximum altitude: 3050 m (10,000 ft) & 5°C - 28°C (41°F - 82°F) 
Maximum rate of temperature change: 5°C/hr (41°F/hr) for tape drive, 20°C/hr (68°F/hr) for HDDs
Server off:
Temperature: 5°C to 45°C (41°F - 113°F) 
Relative humidity: 8% - 85% 
Maximum dew point: 27°C (80.6°F)
Storage:
Temperature: 1°C to 60°C (33.8°F - 140°F) 
Altitude: 3050 m (10,000 ft) 
Relative humidity: 5% - 80% 
Maximum dew point: 29°C (84.2°F)
Shipping:
Temperature: -40°C to 60°C (-40°F - 140°F) 
Altitude: 10,700 m (35,105 ft) 
Relative humidity: 5% - 100% 