Bushing for tube
ass'y
15 mm
Outdoor
Indoor
Wall
Sleeve for
tube ass'y
ø70 through hole
Putty or caulking compound
Approx. 5 - 7 mm
12.2 Indoor Unit 
12.2.1  How to Fix Installation Plate 
The mounting wall is strong and solid enough to prevent if from the vibration. 
 
The centre of installation plate should be at 
more than 450 mm at right and left of the wall. 
 
The distance from installation plate edge to 
ceiling should more than 67mm. 
 
From installation plate left edge to unit’s left side 
is 74mm. 
 
From installation plate right edge to unit’s right 
side is 94mm. 
 
 
: For left side piping, piping connection for liquid should be about 15mm from this line. 
B  
: For left side piping, piping connection for gas should be about 45mm from this line. 
 
: For left side piping, piping connection cable should be about 800mm from this line. 
 
1.  Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider 
using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with the 
thread and using a level gauge. 
2.  Drill the piping plate hole with ø70mm hole-core drill. 
o
 
Line according to the left and right side edge of the installation plate. The meeting point of the extended 
line is the centre of the hole. Another method is by putting measuring tape at position as shown in the 
diagram above. The hole centre is obtained by measuring the distance namely 150mm and 125mm for 
left and right hole respectively. 
o
 
Drill the piping plate hole at either the right or left and the hole should be slightly slanted to the outdoor 
side. 
 
12.2.2  To Drill a Hole in the Wall and Install a Sleeve of Piping 
1.  Insert the piping sleeve to the hole. 
2.  Fix the busing to the sleeve. 
3.  Cut the sleeve until it extrudes about 15mm from the wall  
 
 
 
4.  Finish by sealing the sleeve with putty or caulking compound at the 
final stage.  
 