Overview
8-port RS-232/422/485 serial device servers
NPort® 5600-8-DTL device servers can conveniently and transparently
connect 8 serial devices to an Ethernet network, allowing you to
network your existing serial devices with basic configurations. You
can both centralize management of your serial devices and distribute
management hosts over the network.The NPort® 5600-8-DTL device
servers have a smaller form factor than our 19-inch models, making
them a great choice for applications needing additional serial ports
when mounting rails are not available.
connect 8 serial devices to an Ethernet network, allowing you to
network your existing serial devices with basic configurations. You
can both centralize management of your serial devices and distribute
management hosts over the network.The NPort® 5600-8-DTL device
servers have a smaller form factor than our 19-inch models, making
them a great choice for applications needing additional serial ports
when mounting rails are not available.
Convenient Design for RS-485 Applications
The NPort® 5650-8-DTL device servers support selectable 1 KΩ
and 150 KΩ pull high/low resistors and a 120 Ω terminator. In some
critical environments, termination resistors may be needed to prevent
and 150 KΩ pull high/low resistors and a 120 Ω terminator. In some
critical environments, termination resistors may be needed to prevent
the reflection of serial signals. When using termination resistors, it
is also important to set the pull high/low resistors correctly so that
the electrical signal is not corrupted. Since no set of resistor values
is universally compatible with all environments, NPort® 5600-8-DTL
device servers use DIP switches to allow users to adjust termination
and pull high/low resistor values manually for each serial port.
is also important to set the pull high/low resistors correctly so that
the electrical signal is not corrupted. Since no set of resistor values
is universally compatible with all environments, NPort® 5600-8-DTL
device servers use DIP switches to allow users to adjust termination
and pull high/low resistor values manually for each serial port.
LED Indicators to Ease Your Maintenance Tasks
The System LED, Serial Tx/Rx LEDs, and Ethernet LEDs (located on the
RJ45 connector) provide a great tool for basic maintenance tasks and
help engineers analyze problems in the field. The NPort® 5600’s LEDs
not only indicate current system and network status, but also help field
engineers monitor the status of attached serial devices.
RJ45 connector) provide a great tool for basic maintenance tasks and
help engineers analyze problems in the field. The NPort® 5600’s LEDs
not only indicate current system and network status, but also help field
engineers monitor the status of attached serial devices.
›
8 Serial ports supporting RS-232/422/485
›
Compact desktop design
›
10/100M auto-sensing Ethernet
›
Built-in 15 KV ESD protection for all serial signals
›
Configure via Telnet/Web/Windows utility
›
Socket modes: TCP server/TCP client/UDP/Real COM
›
SNMP MIB-II for network management
Appearance
Serial ports
NPort® 5610-8-DTL: DB9, RS-232
NPort® 5650-8-DTL: DB9, RS-232/422/485
NPort® 5610-8-DTL: DB9, RS-232
NPort® 5650-8-DTL: DB9, RS-232/422/485
LED indicators
Ethernet
RJ45 10/100 Mbps
Power input
Power Jack (12 to 48 VDC)
Reset button
Ethernet Interface
Number of Ports: 1
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Speed: 10/100 Mbps, auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 KV built-in
Serial Interface
Number of Ports: 8
Serial Standards:
NPort 5610-8-DTL: RS-232
NPort 5650-8-DTL/5650I-8-DTL: RS-232/422/485
Connector: DB9 male
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection (NPort 5650I-8-DTL only)
Serial Standards:
NPort 5610-8-DTL: RS-232
NPort 5650-8-DTL/5650I-8-DTL: RS-232/422/485
Connector: DB9 male
Serial Line Protection:
15 KV ESD protection for all signals
2 KV isolation protection (NPort 5650I-8-DTL only)
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Terminator for RS-485: 120 Ω
control)
Pull High/Low Resistor for RS-485: 1 KΩ, 150 KΩ
Terminator for RS-485: 120 Ω
Serial Communication Parameters
Data Bits: 5, 6, 7, 8
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate: 50 bps to 921.6 Kbps
Stop Bits: 1, 1.5, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate: 50 bps to 921.6 Kbps
Serial Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND