Листовка для Moxa EDS-P206A-4PoE-S-SC-T EDS-P206A-4POE-S-SC-T
Модели
EDS-P206A-4POE-S-SC-T
1
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Industrial Ethernet Solutions
EDS-P206A-4PoE Series
Introduction
The EDS-P206A-4PoE switches are smart, 6-port, unmanaged Ethernet
switches supporting PoE (Power-over-Ethernet) on ports 1 to 4. The
switches are classified as power source equipment (PSE), and when
used in this way, the EDS-P206A-4PoE switches enable centralization
of the power supply and provide up to 30 watts of power per port. The
switches supporting PoE (Power-over-Ethernet) on ports 1 to 4. The
switches are classified as power source equipment (PSE), and when
used in this way, the EDS-P206A-4PoE switches enable centralization
of the power supply and provide up to 30 watts of power per port. The
switches can be used to power IEEE 802.3af/at compliant powered
devices (PD), eliminating the need for additional wiring, and support
IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, MDI/MDI-X
auto-sensing to provide an economical solution for your industrial
Ethernet network.
devices (PD), eliminating the need for additional wiring, and support
IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, MDI/MDI-X
auto-sensing to provide an economical solution for your industrial
Ethernet network.
›
IEEE 802.3af/at compliant PoE and Ethernet combo ports
›
Up to 30 watts per PoE port
›
24/48 VDC wide range redundant power inputs
›
Intelligent power consumption detection and classification
›
Redundant dual VDC power inputs
›
-40 to 75°C operating temperature range (T models)
Specifications
6-port IEEE 802.3af/at PoE+ unmanaged Ethernet switches
Technology
Standards:
IEEE 802.3af/at for Power-over-Ethernet
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
Processing Type: Store and Forward
Flow Control: IEEE 802.3x flow control, back pressure flow control
IEEE 802.3af/at for Power-over-Ethernet
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
Processing Type: Store and Forward
Flow Control: IEEE 802.3x flow control, back pressure flow control
Switch Properties
MAC Table Size: 1 K
Packet Buffer Size: 512 KB
Packet Buffer Size: 512 KB
Interface
Fiber Ports: 100BaseFX ports (SC/ST connector)
RJ45 Ports: 10/100BaseT(X) auto negotiation speed, Full/Half duplex
mode, and auto MDI/MDI-X connection
PoE Pinout: V-, V-, V+, V+ for pin 1, 2, 3, 6 (Endspan, MDI-X
Alternative A)
LED Indicators: PWR1, PWR2, 10/100M, PoE
RJ45 Ports: 10/100BaseT(X) auto negotiation speed, Full/Half duplex
mode, and auto MDI/MDI-X connection
PoE Pinout: V-, V-, V+, V+ for pin 1, 2, 3, 6 (Endspan, MDI-X
Alternative A)
LED Indicators: PWR1, PWR2, 10/100M, PoE
Optical Fiber
100BaseFX
Multi-mode
Single-mode
Wavelength
1300 nm
1310 nm
Max. TX
-10 dBm
0 dBm
Min. TX
-20 dBm
-5 dBm
RX Sensitivity
-32 dBm
-34 dBm
Link Budget
12 dB
29 dB
Typical Distance
5 kma
4 kmb
40 kmc
Saturation
-6 dBm
-3 dBm
a. 50/125 μm, 800 MHz*km fiber optic cable
b. 62.5/125 μm, 500 MHz*km fiber optic cable
c. 9/125 μm single-mode fiber optic cable
Power Requirements
Input Voltage: 24/48 (20 to 60 V) VDC, redundant inputs
Input Current: Max 7.5 A @ 24 VDC (supports up to 4 ports at 30
watts per PoE port)
Overload Current Protection: Present
Connection: 1 removable 4-contact terminal block
Reverse Polarity Protection: Present
Input Current: Max 7.5 A @ 24 VDC (supports up to 4 ports at 30
watts per PoE port)
Overload Current Protection: Present
Connection: 1 removable 4-contact terminal block
Reverse Polarity Protection: Present
Physical Characteristics
Housing: Metal, IP30 protection
Dimensions: 50.3 × 115 × 70 mm (1.98 x 4.53 x 2.76 in)
Weight: 375 g
Installation: DIN-Rail mounting, wall mounting (with optional kit)
Dimensions: 50.3 × 115 × 70 mm (1.98 x 4.53 x 2.76 in)
Weight: 375 g
Installation: DIN-Rail mounting, wall mounting (with optional kit)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
Safety: UL 69050-1, UL 508
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Note: Please check Moxa’s website for the most up-to-date certification status.
MTBF
(mean time between failures)
Time: 645,138 hrs
Database: Telcordia (Bellcore), GB
Database: Telcordia (Bellcore), GB