Physical and electrical specifications
Dimensions and weight:
Height: 86 mm (3.4 in.)
Width: 447 mm (17.6 in.)
Depth: 749 mm (29.5 in.)
Weight: 
Minimum configuration: 16.4 kg (36.2 lb).
o
Maximum configuration: 28.2 kg (62.2 lb).
o
Supported environment:
Air temperature
Server on: 5 °C - 40 °C (41.0 °F - 104 °F); altitude: 0 - 915 m (3,000 ft).
o
Server on: 5 °C - 32 °C (41.0 °F - 89.6 °F); altitude: 915 - 2,134 m (7,000 ft).
o
Server on: 5 °C - 28 °C (41.0 °F - 82.4 °F); altitude: 2,134 - 3,050 m (10,000 ft).
o
Server off: 5 °C - 45 °C (41.0 °F - 113 °F).
o
Shipment: -40 °C - 60 °C (-40 °F - 140 °F).
o
Humidity:
Server on: 8% - 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr.
o
Server off: 8% - 80%, maximum dew point 27 °C.
o
Shipment: 5% - 100%.
o
Design to ASHRAE Class A3, ambient of 35 °C - 40 °C, with relaxed support:
Support cloud like workload with no performance degradation acceptable (Turbo-Off).
o
Under no circumstance can any combination of worst case workload and configuration result in 
o
system shutdown or design exposure at 40 °C.
Electrical
Models with 900 W AC hot-swap power supplies:
o
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 10 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.14 kVA
o
Maximum configuration: 0.99 kVA
o
Models with 750 W AC hot-swap power supplies:
o
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 8.9 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.14 kVA
o
Maximum configuration: 0.85 kVA
o
Models with 550 W AC hot-swap power supplies:
o
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 6.5 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
o
Maximum configuration: 0.66 kVA
o