Справочник Пользователя для Toshiba RAS-107SKV-E4

Скачать
Страница из 4
Capacity control = Variable 
TOSHIBA CARRIER (THAILAND) CO., LTD.
144/9 Moo 5, Bangkadi Industrial Park, Tivanon Road,
Tambol Bangkadi, Amphur Muang, Pathumthani 12000 THAILAND
Appliance - Split type air conditioner 
Outdoor unit
Single Inverter
RAS-107SAV-E4
Indoor unit
Hi-wall - Avant
RAS-107SKV-E4
Function 
Cooling
Y
Heating - Average
Y
Heating - Warmer
N
Heating - Colder
N
Design load 
cooling
Pdesignc
2,0
kW
heating/Average
Pdesignh
2,8
kW
Seasonal efficiency 
cooling
SEER
6,00
A+
heating/Average
SCOP(A)
3,90
A
Cooling 
Capacity 
Declared capacity for cooling at indoor temperature 27(19)°C and outdoor 
temperature Tj 
Efficiency 
Declared Energy efficieny ratio for cooling at indoor temperature 27(19)°C 
and outdoor temperature Tj 
Tj=35
Pdc
2,00
kW
Tj=35
EERd
3,73
Tj=30
Pdc
1,47
kW
Tj=30
EERd
6,76
Tj=25
Pdc
1,56
kW
Tj=25
EERd
9,20
Tj=20
Pdc
1,84
kW
Tj=20
EERd
12,72
Heating (Average climate) 
Capacity 
Declared capacity for heating/Average season, at indoor temperature 20 °C and 
outdoor temperature Tj 
Efficiency 
Declared coefficient of performance/Average season, at indoor 
temperature 20 °C and outdoor temperature Tj 
Tj=-7°C
Pdh
2,48
kW
Tj=-7°C
COPd
2,57
Tj=2°C
Pdh
1,51
kW
Tj=2°C
COPd
3,80
Tj=7°C
Pdh
0,97
kW
Tj=7°C
COPd
5,37
Tj=12°C
Pdh
1,25
kW
Tj=12°C
COPd
6,09
Tj=bivalent temperature
Pdh
2,48
kW
Tj=bivalent temperature
COPd
2,57
Tj=operation limit
Pdh
2,08
kW
Tj=operation limit
COPd
2,46
Bivalent temperature
-7
°C
Operation limit temperature
-10
°C
Electricity 
Electric power input in power modes other than "on mode" 
Seasonal electricity consumption 
off mode
Poff
0,008
kW
cooling
QCE
117
kWh/a
standby mode
Psb
0,008
kW
heating/Average
QHE/A
1005
kWh/a
thermostat-off mode
Pto
0,037
kW
heating/Warmer
QHE/B
_
kWh/a
Page 1 of 2
05/03/2013
http://ecodesign.toshiba-airconditioning.eu/en/system-details?system=4d2b8312e37b4...