GB INSTALLATION AND OPERATING MANUAL
Dimmer T39.07 / T39.08 / T46.03
Controlling and dimming is effected by pushing and turning the actuating button.
Pushing the actuating button:
Pushing the actuating button:
ON - OFF
Turning the actuating button:
dimming
The dimmer is designed for installation in switch boxes in accordance with
DIN 49073.
DIN 49073.
Technical data:
Type
T39.07
T39.08
T46.03
Nominal voltage
230 V~ +/-10%, 50 Hz
Power W
7-110W / VA
20-250W / VA
15-150W / VA
Operating principle
leading-edge dimmer
trailing-edge
dimmer
Load types:
Dimmable
energy-saving lamps
Dimmable
LED lamps
LV halogen with
magnetic transformer
magnetic transformer
LV halogen with
electronic transformer
electronic transformer
230 V incandescent
lamps
lamps
230 V halogen lamps
Switch
pushbutton / two-way
Wire range
Lines from
to
massive per terminal
2x 1.5mm²
2x 2.5mm²
Fuse
T1AH 250V
T2AH 250V
electronic
Connection diagram
A / B
Overtemperature
protection through
protection through
(overload protection)
Thermal fuse, which
– after
having triggered
– puts the device
permanently out of operation for
safety reasons!
safety reasons!
Thermal switch,
which
which
– after having
triggered
– puts the
device out of
operation until it has
cooled down!
When the device
has cooled down, it
is switched on
again.
operation until it has
cooled down!
When the device
has cooled down, it
is switched on
again.
Two-way circuit:
A)
A two-way circuit with 2 dimmers is not possible!
On-off circuit:
B)
Assembly:
1. Switch off the power
2. Remove the rotary button (1)
by turning it further than the stop
3. Remove the nut (2)
4. Remove the cover (3)
5. Connect the device according to
the connection diagram
6. Use mounting claws or screws
to fix the device in the flush box.
7. Mount the cover.
8. Switch on the power
The dimmer heats up during operation because a small part of the connected load
is converted into heat. The nominal power specified applies if the dimmer is
installed in a massive stone wall. If the dimmer is installed in a wall of aerated
concrete, wood, gypsum plasterboard or a surface-type housing, the maximum
connected load must be reduced by at least 20%. This reduction is also necessary
if several dimmers are installed in a combination or if the device heats up due to
other heat sources.
is converted into heat. The nominal power specified applies if the dimmer is
installed in a massive stone wall. If the dimmer is installed in a wall of aerated
concrete, wood, gypsum plasterboard or a surface-type housing, the maximum
connected load must be reduced by at least 20%. This reduction is also necessary
if several dimmers are installed in a combination or if the device heats up due to
other heat sources.
Reduction of the maximum load specified on the dimmer
depending on the ambient temperature
Setting the basic brightness (T39.07 and T39.08):
To set the basic brightness, set the actuating button to the left stop (minimum
brightness). Now use a screw driver to set the desired basic brightness on the
potentiometer.
Pursuant to EN 60669-2-1 the basic value should be set in such a way that the
light visibly glows over the entire load range (at nominal voltage
light visibly glows over the entire load range (at nominal voltage
– 10%) when it is
set to dark position.
Transformer adjustment and/or max. value (T46.03):
Should the light flicker when it is set to maximum brightness, the maximum value
for flicker-free operation can be set via the setting option transformer adjustment.
for flicker-free operation can be set via the setting option transformer adjustment.
To set that value, set the actuating button to the right stop (maximum brightness).
Now use a screw driver to set the maximum possible flicker-free brightness on the
potentiometer transformer adjustment.
Now use a screw driver to set the maximum possible flicker-free brightness on the
potentiometer transformer adjustment.
In case of malfunction:
Should the dimmer no longer function, please check the connected lamps or the
fuse (39.07 and T39.08) installed in the dimmer.
fuse (39.07 and T39.08) installed in the dimmer.
You will find a spare fuse in the upper shaft of the fuse holder.
If necessary, only replace the fuse by fuses with the same rating and of the same
type!
If necessary, only replace the fuse by fuses with the same rating and of the same
type!
Notes on safety:
Work on the 230V mains must only be carried out by a certified
electrician, taking into consideration the nationally valid regulations
(e.g. DIN VDE).
electrician, taking into consideration the nationally valid regulations
(e.g. DIN VDE).
All types of work must only be carried out when the mains voltage
is disconnected.
is disconnected.
Non-observance of the installation instructions may lead to a damaged device, fire
or other dangers.
The warranty expires if the device is opened or tampered with.
Observance of this manual is part of our terms of guarantee.
19.553.00 GB
Rev. 01/ 12