GB                      INSTALLATION AND OPERATING MANUAL 
 
Dimmer T39.07 / T39.08 / T46.03 
 
Controlling and dimming is effected by pushing and turning the actuating button. 
Pushing the actuating button:  
ON - OFF
 
Turning the actuating button:  
dimming 
 
The dimmer is designed for installation in switch boxes in accordance with  
DIN 49073.
 
 
Technical data:
 
Type 
T39.07
 
T39.08
 
T46.03
 
Nominal voltage 
230 V~  +/-10%,  50 Hz
 
Power W  
7-110W / VA
 
20-250W / VA
 
15-150W / VA
 
Operating principle 
leading-edge dimmer
 
trailing-edge 
dimmer
 
Load types:
 
 
Dimmable 
 
energy-saving lamps
 
 
 
 
Dimmable 
 
LED lamps
 
 
 
 
LV halogen with 
magnetic transformer
 
 
 
 
LV halogen with 
electronic transformer
 
 
 
 
230 V incandescent 
lamps
 
 
 
 
230 V halogen lamps
 
 
 
 
Switch 
pushbutton / two-way
 
Wire range 
Lines from 
                 to
 
massive per terminal 
2x 1.5mm² 
2x 2.5mm² 
 
Fuse 
T1AH 250V
 
T2AH 250V
 
electronic
 
Connection diagram 
A / B
 
Overtemperature 
protection through 
(overload protection)
 
Thermal fuse, which 
– after 
having triggered 
– puts the device 
permanently out of operation for 
safety reasons!
 
Thermal switch, 
which 
– after having 
triggered 
– puts the 
device out of 
operation until it has 
cooled down! 
When the device 
has cooled down, it 
is switched on 
again.
 
 
 
Two-way circuit: 
A)  
 
 
 
 A two-way circuit with 2 dimmers is not possible! 
 
 
On-off circuit: 
  
B)  
     
 
 
 
 
 
 
 
 
 
 
Assembly: 
 
 
1. Switch off the power 
2. Remove the rotary button (1) 
by turning it further than the stop 
3. Remove the nut (2) 
4. Remove the cover (3) 
5. Connect the device according to  
the connection diagram 
6. Use mounting claws or screws  
to fix the device in the flush box. 
7. Mount the cover. 
8. Switch on the power 
 
 
 
 
 
 
The dimmer heats up during operation because a small part of the connected load 
is  converted  into  heat.  The  nominal  power  specified  applies  if  the  dimmer  is 
installed  in  a  massive  stone  wall.  If  the  dimmer  is  installed  in  a  wall  of  aerated 
concrete,  wood,  gypsum  plasterboard  or  a  surface-type  housing,  the  maximum 
connected load must be reduced by at least 20%. This reduction is also necessary 
if  several  dimmers  are  installed  in  a  combination  or  if  the  device  heats  up  due  to 
other heat sources. 
 
 
Reduction of the maximum load specified on the dimmer 
depending on the ambient temperature 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Setting the basic brightness (T39.07 and T39.08): 
 
To  set  the  basic  brightness,  set  the  actuating  button  to  the  left  stop  (minimum 
brightness).  Now  use  a  screw  driver  to  set  the  desired  basic  brightness  on  the 
potentiometer.
 
Pursuant  to  EN  60669-2-1  the  basic  value  should  be  set  in  such  a  way  that  the 
light visibly glows over the entire load range (at nominal voltage 
– 10%) when it is 
set to dark position. 
 
Transformer adjustment and/or max. value (T46.03): 
 
Should the light flicker when it is set to maximum brightness, the maximum value 
for flicker-free operation can be set via the setting option transformer adjustment. 
 
To set that value, set the actuating button to the right stop (maximum brightness). 
Now use a screw driver to set the maximum possible flicker-free brightness on the 
potentiometer transformer adjustment.
 
 
In case of malfunction: 
 
Should  the  dimmer  no  longer  function,  please  check  the  connected  lamps  or  the 
fuse (39.07 and T39.08) installed in the dimmer. 
 
You will find a spare fuse in the upper shaft of the fuse holder. 
If necessary, only replace the fuse by fuses with the same rating and of the same 
type! 
 
Notes on safety: 
 
Work on the 230V mains must only be carried out by a certified 
electrician, taking into consideration the nationally valid regulations 
(e.g. DIN VDE). 
 
All types of work must only be carried out when the mains voltage 
is disconnected. 
 
 
 
Non-observance of the installation instructions may lead to a damaged device, fire 
or other dangers. 
 
The warranty expires if the device is opened or tampered with. 
 
Observance of this manual is part of our terms of guarantee. 
 
 
19.553.00 GB 
Rev. 01/ 12
 
 
 
 
Temperature in 
°C 
 
Power in %
 
 
0
 
10
 
20
 
30
 
40
 
50
 
60
 
70
 
80
 
90
 
100
 
-10
 
0
 
10
 
20
 
30
 
40
 
50
 
60
 
70
 
80
 
90
 
100
 
1
2
3