The spot may only be operated when in accordance with the allowable position for use. Please ensure, that
the angle of inclination is set within the following parameters:
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
OPERATION
After you connected the spot to the mains, you can control the spots via your lighting controller.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1)  All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2)  There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3)  The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a