Техническая Спецификация для Plastidip Liquid rubber coating spray Colour Neon green 61090017 400 ml 61090017

Модели
61090017
Скачать
Страница из 9
Page 3/9
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 28.02.2012
Revision: 28.02.2012
Version 2
Trade name: PLASTI DIP® FLÜSSIGGUMMI SPRAY
(Contd. of page 2)
34.0
CAS: 78+93+3
EINECS: 201+159+0
butanone
 Xi R36
 F  R11
R66+67
 
Flam. Liq. 2, H225
 
Eye Irrit. 2, H319; STOT SE 3, H336
2.5+10%
CAS: 142+82+5
EINECS: 205+563+8
heptane
 Xn R65
 Xi  R38
 F  R11
 N  R50/53
R67
 
Flam. Liq. 2, H225
 
Asp. Tox. 1, H304
 
Aquatic Acute 1, H400; Aquatic Chronic 1, H410
 
Skin Irrit. 2, H315; STOT SE 3, H336
2.5+10%
Additional information: a) For the wording of the listed risk phrases refer to section 16.
4 First aid measures
Description of first aid measures
After inhalation:
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms
persist.
After skin contact:
Immediately rinse with water.
Remove and wash contaminated clothing.
After eye contact:
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
After swallowing:
Rinse out mouth and then drink plenty of water.
Do not induce vomiting.
Information for doctor:
Most important symptoms and effects, both acute and delayed
No further relevant information available.
Indication of any immediate medical attention and special treatment needed
If swallowed or in case of vomiting, danger of entering the lungs.
5 Firefighting measures
Extinguishing media
Suitable extinguishing agents:
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
For safety reasons unsuitable extinguishing agents: Water with full jet
Special hazards arising from the substance or mixture
Can form explosive gas+air mixtures.
In case of fire, the following can be released:
Carbon monoxide and carbon dioxide
Advice for firefighters
Protective equipment: Wear self+contained respiratory protective device.
Additional information
Dispose of fire debris and contaminated fire fighting water in accordance with official regulations.
 GB