Overview
INSYS GPRS 5.0 Ethernet
12
Dez-06
3.4.3 Power Supply
The INSYS GPRS Ethernet requires a power supply of 10 to 60 V (DC) at a maximum of 5%
ripple.
ripple.
Caution - No overvoltage protection!
The INSYS GPRS Ethernet does not have a fuse.
Surges and excessive voltages may result in the destruction of the de-
vice.
The INSYS GPRS Ethernet does not have a fuse.
Surges and excessive voltages may result in the destruction of the de-
vice.
The following table shows the values that were determined for a signal field strength of
26 and an ambient temperature of
77°F (25°C). The current consumption and therefore
the power consumption may increase during poor network conditions. The threshold
value tolerances are subject to the typical fluctuations. A maximum of one value may be
operated in the threshold value range.
value tolerances are subject to the typical fluctuations. A maximum of one value may be
operated in the threshold value range.
These are average values for estimating the current consumption. The current consump-
tion during data transmissions may also increase if the antenna is not adjusted correctly.
This can occur for the following cases:
tion during data transmissions may also increase if the antenna is not adjusted correctly.
This can occur for the following cases:
The antenna and/or the antenna cable are not adjusted to 50 Ω impedance.
The antenna that is being used is misaligned due to the situation at the instal-
The antenna that is being used is misaligned due to the situation at the instal-
lation site (metal parts, …).
State:
Standby
Standby
State:
CSD Data transmission
CSD Data transmission
State:
GPRS Data transmission
GPRS Data transmission
Current consumption type at
10 V (DC)
10 V (DC)
140 mA
195 mA
290 mA
Current consumption type at
24 V (DC)
24 V (DC)
60 mA
84 mA
121 mA
Current consumption type at
36 V (DC)
36 V (DC)
42 mA
60 mA
60 mA
Power consumption approx.
1.4 W
2 W
2.9 W