miniLAB 1008 User's Guide  
Functional 
Details 
Table 4-4. Sample channel gain queue list 
Element  
Channel  
Range 
0  
CH0  
BIP10V  
1  
CH0  
BIP5V 
2  
CH7  
BIP10V 
3  
CH2  
BIP1V 
 
 
When a scan begins with the gain queue enabled, the miniLAB 1008 reads the first 
element, sets the appropriate channel number and range, and then acquires a sample. The 
properties of the next element are then retrieved, and another sample is acquired. This 
sequence continues until all elements in the gain queue have been selected. When the 
end of the channel list is detected, the sequence returns to the first element in the list.  
This sequence repeats until the specified number of samples is gathered. You must 
carefully match the gain to the expected voltage range on the associated channel—
otherwise, an over range condition can occur. Although this condition does not damage 
the miniLAB 1008, it does produce a useless full-scale reading. It can also introduce a 
long recovery time from saturation, which can affect the next measurement in the queue. 
Digital connector cabling 
Table 4-5 lists the digital I/O connector, applicable cables and accessory equipment. The 
x in the compatible cable name indicates the length of the cable. 
Table 4-5. Digital connector and accessory equipment 
Connector type 
37 D-Type, shielded 
C37FF-x (Figure 4-13) 
C37FFS- x (Figure 4-14) 
Compatible cables 
C37FM- x (Figure 4-15) 
Compatible accessory products 
CIO-MINI37 
SSR-RACK24 
SSR-RACK08 
CIO-ERB24 
CIO-ERB08 
 
 
4-16