Техническая Спецификация для Infineon Technologies KITXMC2GOXMC1100V1TOBO1

Скачать
Страница из 57
XMC1100
XMC1000 Family
Electrical Parameter
 
Data Sheet
25
V1.4, 2014-05
 
3.1.3
Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation and reliability of the XMC1100. All parameters specified in the following tables
refer to these operating conditions, unless noted otherwise.
Table 10
Operating Conditions Parameters
Parameter
Symbol
Values
Unit
Note / 
Test Condition
Min.
Typ.
Max.
Ambient Temperature
T
A
 SR
-40
85
°C
Temp. Range F
-40
105
°C
Temp. Range X
Digital supply voltage
1)
1) See also the Supply Monitoring thresholds, 
.
V
DDP
 SR
1.8
5.5 V
MCLK Frequency
f
MCLK
 CC
33.2
MHz
CPU clock
PCLK Frequency
f
PCLK
 CC
66.4
MHz
Peripherals 
clock
Subject to Agreement on the Use of Product Information