Number  Axis Parameter 
 
Description 
Range 
Access 
11 
left limit switch status 
The logical state of the left limit switch (in three switch 
mode) 
0/1 
12 
right limit switch disable  if set, deactivates the stop function of the right switch 
0/1 
RWE 
13 
left limit switch disable 
deactivates  the  stop  function  of  the  left  switch  resp. 
reference switch if set. 
0/1 
RWE 
14 
steprate prescaler 
Currently not used, see parameters no. 153 and 154 
 
 
4.2  Advanced  axis  parameters  (all  TMCL  stepper  motor  modules 
except the TMCM-100) 
These parameters are only needed if the desired needs can not be met by setting the basic parameters listed in 
section  4.1.  Some  of  these  parameters  influence  the  TMC428  directly  so  that  advanced  understanding  of  the 
TMC428  chip  is  needed.  There  are  even  some  parameters  that  should  only  be  changed  if  recommended  by 
TRINAMIC. Please note that these paramters are not available on the TMCM-100 module. 
 
Number  Parameter 
 
Description 
Range 
Access 
130 
minimum speed 
Should  always  be  set  1  to  ensure  exact  reaching  of  the 
target position. Do not change! 
0... 2047
 
RWE 
135 
actual acceleration 
The current acceleration (read only). 
0... 2047  R 
136 
acceleration threshold  specifies  the  threshold  between  low  and  high  acceleration 
values for the parameters 144&145. Normally not needed. 
0... 2047  RWE 
137 
acceleration divisor 
A  ramping  parameter,  can  be  adjusted  in  special  cases, 
automatically  calculated  by  setting  the  maximum 
acceleration  (e.g.  during  normal  initialisation).  See  the 
TMC428 data sheet for details. Normally no need to change. 
0…13
 
RWE 
138 
ramp mode 
In version 2.16 and later: automatically set when using ROR, 
ROL, MST and MVP.  
0: position mode. Steps are generated, when the parameters 
actual position and target position differ. Trapezoidal speed 
ramps are provided. 
2:  velocity  mode.  The  motor  will  run  continuously  and  the 
speed  will  be  changed  with  constant  (maximum) 
acceleration, if the parameter "target speed" is changed.  
For  special  purposes,  the  soft  mode  (value  1)  with 
exponential decrease of speed can be selected.  
0/1/2 
RWE 
139 
interrupt flags 
Must not be modified. See the TMC 428 datasheet for details.  16bits 
RW