Справочник Пользователя для Behringer B-Control Fader BCF2000-WH

Скачать
Страница из 22
16
B-CONTROL  FADER  BCF2000/B-CONTROL  ROTARY  BCR2000
2d-   Just like “2d”, but when the value is 0, no LED lights up.
Bar    Bar display: when the value is changed, all LEDs light up
successively (for volume etc.).
Bar-Just like bar display, but when the value is 0, no LED
lights up.
Sprd    Spread: When the value is 0, the upper middle LED lights
up; when the value is increased, the LED circle gradually
lights up in both directions (left and right).
Pan    In the middle position (value = 64), only the upper middle
LED is on. With lower values, the LED circle lights up
toward the left; with higher values, the LED circle lights
up toward the right (panorama adjustment).
Qual    (Quality Q) has the opposite effect from spread: the LED
circle lights up gradually when you decrease the value.
This  setting  is  used  for  indicating  filter  quality  with
parametric equalizers.
Cut    Cutoff is optimal for controlling the cutoff frequency of a
low-pass filter, for example on a synthesizer. When the
value is 0, all LEDs light up. The LEDs go out successively
as you increase the value.
Damp   Damping: used for damping filters. When the value is 0,
the outer right LED lights up. If the values are increased,
the LED circle fans out from right to left until all LEDs
light up. This way, increasing damping is best represented
when a value goes up.
Encoder LED display (BCR2000):
1d
(1 digit): Only one LED lights up at a time (standard setting).
1d-   The LED circle operates similar to “1d”, but when the value
is 0, no LED lights up.
Fader functions (BCF2000):
Move If you move the fader by hand, it sends a new value directly.
In doing so, jumps in the parameter value may occur if the
current value doesn’t correspond to the fader position. This
can sometimes happen because in this mode parameter
feedback doesn’t cause fader movement.
P-UP Pick  up:  The  fader  ignores  the  parameter  feedback.
However, value jumps are avoided because the fader only
sends values if the current value (different from the fader
setting) is exceeded.
Mot
Motor:  With  parameter  feedback,  the  motorized  fader
engages automatically and always indicates the current
value.
Foot controller function:
Move   The pedal immediately sends value changes. Value jumps
may result.
P-UP    Pick-Up: The foot pedal become active and sends values
only if the set value is exceeded.
SWITCH-type elements:
SWITCH-type  control  elements  have  three  different  modes:
“Toggle On”, “Toggle Off” and “Increment”. Toggle On is similar
to a switching function (e.g. a light switch). Each time you press
the switch, the value sent alternates between the “on” value (set
by encoder 4) and the “off” value (set by encoder 5). This setting
is perfect for triggering drum loops from a sampler (press once =
start, press again = stop).
The  Toggle  Off  mode corresponds  to  a  momentary-contact
button, comparable to the switch of an electric door opener. The
“on” value is sent only as long as the button is pressed. After
releasing the button, the “off” value is sent. Use this control type
to trigger short sound FX or samples (similar to using a keyboard)
by sending Note On and Offs.
The Increment option only works for buttons, and only on CC,
NRPN  and  after  touch  command  types.  This  mode  lets  you
gradually increase the controller value with each new keystroke.
Set up increment size using encoder 7. If you repeatedly press a
4. OPERATION
button, the value sent will be increased each time by the preset
amount selected here. If increment size is set to “10,” values 0,
10, 20, 30 ... 110, 120, 0, 10 and so on will be successively sent
one after another. You can also enter negative values (e.g. -10)
to achieve a gradual decrease in the value. If you use encoders 4
and 5 to delineate the lowest and the highest value that are to be
sent, the values always stay within that range here as well. With
this function, you have the option to use your B-CONTROL to
control software buttons with more than two switch positions.
The value display activated using Push Encoder 8 is identical
for switch and continuous elements. If this value display is active,
the current value is indicated in the four-digit display when you
actuate a control element. The display shows the preset number
again as soon as you release the control element.
4.4 MIDI messages
Program Change:
With the encoders 3 and 4 you can select bank numbers. If a
MIDI  device  contains  more  than  128  presets/programs,  first  a
bank  change  command  has  to  be  sent.  Even  though  this  is  a
controller command, it has to be sent before the program change
(and is therefore adjustable) since it is linked to the preset change.
If the bank select message is not needed, simply select “off”.
Encoder  5  selects  the  program  number.  If  the  selected
control  element  is  a  control  dial  (continuous  type),  the
program number is directly selected when turning the dial.
Pressing the switch directly selects the assigned program
number. This can be useful if you always want to start from
the same preset.
Control Change CC:
A  control  change  consists  of  a  controller  number  and  its
respective  value.  Encoder  3  sets  the  controller  number.  With
buttons, different values can be sent when pressing and releasing
(to be set with encoders 4 and 5). This function is useful if fixed
parameter settings are to be sent.
With faders and control dials (continuous type), the value range
can be determined by using encoders 4 (minimum value) and 5
(maximum value).
+
Alternatively, you can invert the value scale by assigning
127  as  the  minimum  value  and  0  as  maximum  value
(scale inversion). A classic application is the draw bar
control of virtual or digital organs or organ expanders.
If assigning controller 7 (volume) to the faders of the
BCF2000  this  way,  the  signal  becomes  quieter  when
moving up the fader. Moving down the fader is similar
to moving out the draw bars, and the volume increases.
NRPN:
A NRPN is needed if none of the 127 standardized controller
numbers are available for a certain function.
Encoder 3 selects the parameter number. For assigning mixer
faders,  we  recommend  the  high  resolution  (“Absolute  14  bit”),
provided that the control hardware/software supports it.
Note:
Of course, a note can only be assigned to one SWITCH element.
The note is set with encoder 3. Note C3 (C key) corresponds with
note number 60. Encoder 4 sets the note velocity (note volume).
Pitch Bend:
Pitch bend is assignable to only one CONTINUOUS element.
Since this is a type of command with its own status byte, selecting
a MIDI channel (Encoder 2) and Range (Encoder 4) is sufficient.
After Touch:
Normally, “ALL” is selected here. This means that After Touch
affects all notes equally (“Channel Pressure”). If you want to use
a polyphonic After Touch (“Key Pressure”), the single note on
which After Touch should have an effect can be selected using
encoder 3. Since this process is only supported by a few tone
generators, channel After Touch will be best most of the time.
When a switch element has been selected, an “on” and “off” value