Справочник Пользователя для Whirlpool T-K2

Скачать
Страница из 32
Initiating the Appliance 
 
For your safety, read before operating. 
 
WARNING: If you do not follow these 
instructions exactly, a fire or explosion may 
result causing property damage, personal 
injury or loss of life. 
 
a)  This appliance does not have a pilot. It is 
equipped with an electronic ignition device, 
which automatically lights the burner. Do 
not try to light the burner by hand. 
b) 
 
Before operating, check for gas 
accumulation in the area around the 
appliance. Pay special attention near the 
floor, because gas is often heavier than air, 
and it may accumulate near the floor. 
c)  Do not attempt to open the manual gas 
shutoff valve with anything but by hand. 
Never use tools. If the valve will not open 
by hand, do not try to repair it. Instead, call 
a qualified service technician. Force or 
attempted repair may result in a gas leak, 
fire or explosion. 
d)  Do not use this appliance if any part has 
been under water. Immediately call a 
qualified service technician to inspect the 
appliance and to replace any part that may 
have been damaged by being under water. 
 
WARNING: IF YOU SMELL GAS: 
  Do not use any appliance. 
  Do not touch any electric switch, do not 
use any phone in your building. 
  Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 
  If you cannot reach your gas supplier, call 
the fire department. 
 
 
 
 
 
 
 
 
 
 
 
Initial Operation 
 
1.  STOP! Do not operate without reading the 
safety information first! 
2.  Switch off the electrical power supply to the 
heater. 
3.  Do not attempt to light the burner manually.  
4.  Turn the manual gas control valve located 
on the outside of the unit counterclockwise 
to the OFF position. 
5.  Wait five (5) minutes to clear out any gas. 
If you then smell gas, STOP! Follow “b” in 
the “Initiating the Appliance” section above. 
If you do not detect gas, proceed to the 
next step. 
6.  Turn the manual gas control valve located 
on the outside of the unit clockwise to the 
ON position. 
7. Turn on the electrical power to the 
appliance. 
8.  Turn on any tap, and the T-K2 will initiate 
itself. 
9.  If the appliance will not operate, follow the 
instructions in the “Turning Off the Gas 
Supply to the Appliance” section following, 
and call a service technician or gas 
supplier. 
 
TURNING OFF THE GAS SUPPLY TO THE 
APPLIANCE 
 
Close the manual valve on the gas inlet line. 
Turn off the power supply. 
 
 
 
                           
Manifold pressure tap.