Справочник Пользователя для Windsor ENSIGN E50 10070090

Скачать
Страница из 26
MAINTENANCE 
 ENSIGN  86038250  02/12/07 
      4-2 
 
Only qualified 
maintenance 
personnel are to 
perform the following repairs
 
VACUUM MOTOR REPLACEMENT 
1.  Turn off all switches and unplug machine. 
2.  Remove recovery tank. 
3.  Locate the vacuum motor wires and 
disconnect at the connector.  
4.  Remove the vacuum motor. 
5.  Reverse process to install vacuum motor. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
Vacuum Motor Carbon Brushes Replacement (Windsor) 
WARNING: The green 
ground wire must be 
attached for safe operation. 
See wiring diagram. 
End Cap 
Carbon  
Brushes  
If armature commutator is grooved, extremely pitted or not 
concentric, the motor will need to be replaced or sent to a 
qualified service center. 
Important: 
These brushes wear quicker as the length shortens due to 
increased heat. Spring inside brush housing will damage 
motor if brushes are allowed to wear away completely. 
Periodically check the length of the carbon brushes. Replace 
both carbon brushes when either is less than 3/8" (9.5mm) 
long. 
3
8
 [9.5mm]
Important: 
These brushes wear quicker as the length shortens due to 
increased heat. Spring inside brush housing will damage 
motor if brushes are allowed to wear away completely. 
Periodically check the length of the carbon brushes. Replace 
both carbon brushes when either is less than 3/8" (9.5mm) 
long. 
3/8 (9.5mm) 
Vacuum Motor Carbon Brushes Replacement (Ametek) 
Note:  When replacing carbon brushes loosen wire terminal 
BEFORE removing screws on bracket. 
Note:   
Place  
stop in 
groove. 
Wire
Terminal
WARNING: The green 
ground wire must be 
attached for safe operation. 
See wiring diagram. 
End Cap 
Carbon  
Brushes  
Wire Terminal 
If armature commutator is grooved, extremely pitted or not 
concentric, the motor will need to be replaced or sent to a 
qualified service center.