2.  The following applications require a larger feed stand (optional 3” or 4”) to prevent 
material bridging: 
o
  Machines with a total throughput over 200 lbs./hr. 
o
  Machines running regrind larger than 5/16” screen size 
o
  Processes with a high percentage of regrind (>30%) 
o
  Non-free flowing virgin material, i.e. powder 
o
  Consult factory for any special requirements. 
3.  Optimum mounting of the Digital Dosing feeder is shown in Figure 4, with the additive 
being dosed in the first few flights of the feed screw. 
4.  The controller should be remote mounted for operator convenience. The control unit 
must not be exposed to temperatures above 45
° C (115° F), or excessive moisture. 
5.  Electrical connection to process machine: 
   
  Injection Molding:     Connect the “cycle/run” cable (thin, gray two-conductor 
   
   
 
           cable) to a set of dry (NO VOLTAGE) contacts that CLOSE 
   
   
                       for the duration of the screw recovery. (See Figure 5.) 
 
 
 
 
 
 
  
 
       TB #10 
 
 
 
 
 
      
 
       X5 
 
 
 
 
 
 Relay 
contact 
      
 
 
Injection molding 
 
Digital Dosing controller  
 
 
 
 
Figure 5.  Electrical Interface Connection Diagram –                                             
Injection Molding or Extrusion - Constant