Справочник Пользователя для Siemens AT Command Set Cellular Engines Wireless Modules MC35
![Siemens](https://files.manualsbrain.com/attachments/fea10bc852adcb1f4f76708d5daebca542e532b9/common/fit/150/50/c53f5738b57089fc3d6c279e23db7450685a19c9616727fc1f659077967b/brand_logo.png)
AT Command Set
MC35_ATC_01_V04.00
Page 59 of 238
02.04.2002
4.3 AT+CAMM Accumulated call meter maximum (ACMmax) set or query
Test command
AT+CAMM=?
Response
OK
Parameter
OK
Parameter
Read command
AT+CAMM?
Response
TA returns the current ACMmax value.
+CAMM: <acmmax> OK
If error is related to ME functionality:
+CME ERROR: <err>
+CAMM: <acmmax> OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
See write command
Write command
AT+CAMM=
[<acmax>[,<passwd>]]
[<acmax>[,<passwd>]]
Response
TA sets the Advice of Charge related to the accumulated call meter maxi-
mum value in SIM file EF (ACMmax). ACMmax contains the maximum
number of home units allowed to be consumed by the subscriber.
OK
If error is related to ME functionality:
+CME ERROR: <err>
mum value in SIM file EF (ACMmax). ACMmax contains the maximum
number of home units allowed to be consumed by the subscriber.
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
<acmmax> string type; three bytes of the max. ACM value in hexadeci-
mal format (e.g. “00001E” indicates decimal value 30) 000000
disable ACMmax feature 000001-FFFFFF
disable ACMmax feature 000001-FFFFFF
<passwd>
string type
SIM PIN2
Reference
GSM 07.07
Note