28 Installation 
 
(for qualified installers only)
 
© Travis Industries 
4090507 
100-01217_000 
 Termination Requirements 
Venting terminals shall not be recessed into a wall or siding. 
Minimum 9" (229mm) clearance from any door or window 
Minimum 12" (305mm) above any grade, veranda, porch, deck or balcony 
Minimum 3-3/8" (86mm) from outside corner walls  
NOTE: Clearance in accordance with local installation codes and the requirements 
of the gas supplier. 
Minimum 12" (305mm) from inside corner walls  
NOTE: Clearance in accordance with local installation codes and the requirements 
of the gas supplier. 
11" Min.
(279mm)
6" Min.
(152mm)
Roof 
Surface
Roof 
Eaves
Minimum 11" (279mm) clearance below unventilated soffits or roof surfaces 
Minimum 18" (457mm) clearance below ventilated soffits 
Minimum 6" (152mm) clearance below roof eaves 
NOTE: Vinyl surfaces require 24" (610mm) 
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. 
Minimum 12" (305mm) clearance below a veranda, porch, deck or balcony   
NOTE:  Permitted only if veranda, porch, deck, or balcony is fully open on a minumum of two sides beneath the floor. 
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. 
Minimum 48" (1219mm) clearance from any adjacent building 
Minimum 84" (2134mm) clearance above any grade when adjacent to public walkways or driveways 
NOTE: may not be used over a walkway or driveway shared by an adjacent building 
Minimum 9" (229mm) clearance to any nonmechanical air supply inlet to the building or the combustion air inlet to any 
other appliance. 
Minimum 36" (914mm) clearance above any mechanical air supply inlet if within 10’ (3M) horizontally 
Minimum 36" (914mm) from the area above the meter/regulator  (vent outlet)  - this extends 15’ (4.5M) above the regulator 
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. 
Minimum 36" (914mm) from the meter/regulator (vent outlet)  
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. 
M  Minimum 12” (305mm) above the roof line (for vertical terminations) 
Minimum 24” (610mm) horizontal clearance to any surface (such as an exterior wall) – for vertical terminations 
C
B
H
E
G
A
D
F
L
K
J
I
NOTE: Measure clearances to the nearest edge of the exhaust hood. 
A
E
E
M
N
 
• 
Use the vinyl siding standoff when installing on an exterior with vinyl siding. 
• 
Vent termination must not be located where it will become plugged by snow or other material