58 Optional 
Equipment 
 (for qualified installers only)
 
© Travis Industries 
4090507 
100-01217_000 
Extra Room Power Heat Duct 
SKU 98500769 
Special Instructions for 864 ST 
The 864 ST has a removable cover plate shield below the heat duct connections.  This allows more heat 
to be routed to the power heat ducts (see below for details).  Otherwise the heat duct is installed the 
same as an 864TRV (one heat duct kit maximum, manually-controlled on/off operation – see wiring 
diagram below). 
Power Heat Duct Wiring Diagram 
Power Heat Duct Wiring Diagram
 
• 864 TRV
 • 864 ST
 • 864 HH 
(sn 3407-001009 or less)
Hot 
(black)
Common 
(white)
Ground 
(green)
Power Supply
Hot 
(black)
Common 
(white)
Ground 
(green)
Rheostat 
Junction Box
Blower 
Assembly
 
 
-Remove the Heat Shield Cover Plate 
 
Remove and discard the power heat 
duct cover plate.
Remove and discard the circular cover 
plate attached to the heat shield.
NOTE
: an additional power heat 
duct hook-up location is provided 
on the right side (it is along the top 
edge of the fireplace).  
NOTE
: Only one hook-up may be 
used (do not hook up two heat 