Справочник Пользователя для Qualstar 501440 Rev. G

Скачать
Страница из 89
 
6.5 
Installing a Fibre Channel Option 
CAUTION 
Be sure to turn the library’s power off before installing or removing a Fibre Chan-
nel Option. 
6.5.1 Installation 
The following steps outline the actions necessary to install a Fibre Channel Option 
onto a library. 
1. 
Remove power from the TLS: first turn the power switch off and then remove the 
power cord. 
2. 
Using a Phillips screwdriver remove the six screws securing the service panel on 
the rear of the library – refer to Figure 6-9. Depending of the model of library, 
the service panel may not have ventilation slots. Care must be taken to not re-
move the four screws securing the heatsink panels. Save the service panel for 
possible future use. 
 
Phillips Screws (6) 
Do not remove
 these screws
Do not remove 
 these screws 
 
Figure 6-9   Service Panel 
3. 
Place the lower lip of the FCO inside the bottom edge of the service panel open-
ing and tilt the FCO upwards, making sure that the heatsink panel screws align 
501440 Rev. G
 
FCO Type C Installation 
6-11