8.3.15 Air 
Temp 
This value displays the board’s temperature in degrees Celsius. 
8.3.16  CPU Temp (Type A and B FCOs only) 
This value displays the CPU’s temperature in degrees Celsius. This item is not appli-
cable to type C FCO models. 
8.3.17 UPDATE 
This menu item is visible when communications to the Fibre Channel Option is in an 
idle state. Invoking this command will cause the Fibre Channel Option to update the 
configuration and environmental information. 
It takes approximately 35 seconds to obtain new information after the 
UPDATE
 com-
mand has been invoked. 
8.4 
Maintenance\Fibre Channel\ Log (Left or Right) Status Screen 
MFC..............Log 
MFC.........Log Left 
MFC........Log Right 
The Fibre Channel Log status screen displays the Fibre Channel Option’s internal 
event log. The information is provided to assist in troubleshooting problems and is not 
required for normal library operation. The event log is saved in non-volatile memory 
and is not lost when the library power is removed. 
The first line in the status screen indicates the Fibre Channel Option selected. The 
second line contains the event sequence number and a timestamp. Lines three and 
four contain event text description. If the second line ends with an up arrow, newer 
events are available for viewing. If the last line ends with a down arrow, older events 
are available for viewing. These older or newer events can be viewed by using the 
V
 (UP) and W (DOWN) keys to scroll the display. Since the event data is stored in the 
Fibre Channel Option, a small time delay occurs after each request to retrieve the in-
formation for display. 
8-6
 
Maintenance Menu
 
501440 Rev. G