Справочник Пользователя для Novatel GNSS Receiver and Antenna SMART-AG

Скачать
Страница из 76
58
SMART-AG User Manual Rev 2
Appendix B
Commands
B.2 FRESET Clear Selected Data from NVM and Reset
The OEMV freset command is extended to include SMART-AG features. An additional target field, 
userdata (value = 10), resets only the SMART-AG user data NVM, thereby resetting all parameters 
indicated in this document as “Stored in NVM” to factory defaults. Issuing the freset command with 
the “target” field set to standard, resets the userdata NVM as well as OEMV parameters as indicated 
in the OEMV Family Firmware Reference Manual.
 If you issue the FRESET command without any parameters, it is the same as issuing a FRESET 
STANDARD command.
 Table 11:  FRESET Target
Field
Field
Type
ASCII
Value
Binary
Value
Description
Binary
Format
Binary
Bytes
Binary
Offset
1
FRESET 
header
-
-
This field contains the command name 
or the message header depending on 
whether the command is abbreviated 
ASCII, ASCII or binary, respectively.
-
H
0
2
target
Data to be reset by the receiver
Enum
4
H
Binary
ASCII
Description
0
STANDARD
Resets commands, ephemeris, and almanac (default). Also resets all L-
band related data except for subscription information.
1
COMMAND
Resets the stored commands (saved configuration)
2
GPSALMANAC
Resets the stored GPS almanac
3
GPSEPHEM
Resets the stored GPS ephemeris
4
GLOEPHEM
Resets the stored GLONASS ephemeris
5
MODEL
Resets the currently selected model
10
USERDATA
Reset SMART-AG-only commands
11
CLKCALIBRATION
Resets the parameters entered using the CLOCKCALIBRATE command
20
SBASALMANAC
Resets the stored SBAS almanac
21
LAST_POSITION
Resets the position using the last stored position
31
GLOALMANAC
Resets the stored GLONASS almanac