Руководство По Установке для Kenmore Flue Extension for Glass Canopy Chimney Hood for Tall Ceilings

Скачать
Страница из 13
6
WARNING 
To reduce the risk of fire, use only metal ductwork.
1.  Decide where the ductwork will run between the 
hood and the outside.
2.  A straight, short duct run will allow the hood to 
perform most efficiently.
3.  Long duct runs, elbows and transitions will reduce 
the performance of the hood. Use as few of them 
as possible. Larger ducting may be required for best 
performance with longer duct runs.
4.  Install a wall cap or roof cap. Connect round metal 
ductwork to cap and work back towards the hood 
location. Use duct tape to seal the joints between 
ductwork sections.
The minimum hood distance above cooktop MUST NOT 
BE LESS than 24”. 
A maximum of 30” above cooktop is highly recom-
mended for best capture of cooking impurities. 
Distances over 30” are at the installer and users discre-
tion; providing that the ceiling height permits. 
INSTALL THE DUCTWORK
HOOD
12-
3/4
” 
TO
 
CENTER
OF
 
HOOD
 
MOUNTING
BRACKET
 
HOLES
ROUND
 
ELBOW
HOOD
 
MOUNTING
BRACKET
24” 
TO
 30” 
ABOVE
COOKING
 
SURFACE
DECORATIVE
FLUE
 
 6” 
ROUND
 
DUCT
ROOF
 
CAP
 
WALL
 
CAP
3-
3/8
 
DUCT
CENTER
LINE
INSTALL MOUNTING BRACKET
1.  Construct wood wall framing that is flush with 
interior surface of wall studs.
Make sure:
 a)  the  framing  is  centered  over  installation
location.
 b)  the  height  of  the  framing  will  allow  the
mounting bracket to be secured to the framing within 
the dimensions shown.
2.  After wall surface is finished, carefully center and 
level the hood mounting bracket and secure it to 
wall framing with (3) #8 x 1-1/2” mounting screws.
Tighten the screws completely.
Note: Do not use drywall anchors.
NOTES: 
Minimum hood distance above cooktop must 
not be less than 24”.
A maximum of 30” above the cooktop is 
highly recommended for best capture of 
cooking impurities.
Distances over 30” above the cooktop  are 
at  the installer’s and user’s discretion - 
providing that ceiling height and flue length 
permit.
36¾” = bottom of hood 24” above cooktop 
42¾” = bottom of hood 30” above cooktop
MOUNTING BRACKET LOCATION 
(ABOVE 36” HIGH COOKTOP)
C
L
9
4
1
2
FRAMING BEHIND  
DRYWALL
WALL STUDS
1
9
16
CEILING
 
DUCT 
 
            HOOD DISTANCE ABOVE 36” COOK TOP (SEE NOTE 1)
HEIGHT 
METHOD 
24” 
25” 
26” 
27” 
28” 
29” 
30”
 
 
 MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET 
DUCTED OR 
36-3/4”  37-3/4”  38-3/4”  39-3/4”  40-3/4”  41-3/4”  42-3/4”
 
NONDUCTED
9 FEET 
DUCTED OR 
36-3/4” *  37-3/4” *  38-3/4” *  39-3/4” *  40-3/4” *  41-3/4” *  42-3/4” *
 
NONDUCTED
* WITH OPTIONAL FLUE EXTENSION - PART NUMBER 59920.